Web code: YARI3 Web code accessories: ACMEC Web code controls: ACREG
FAN COILS

Fan coils with EC motor

YARDY-I EV3
Cooling capacity 1,9÷8,4 kW
Heating capacity 2,5÷11,8 kW

Floor and ceiling fan coil units with cabinet for recessed wall or false ceiling installation.

Features

Key features

New white RAL 9003 for versions with cabinet
New touch controls
Air'Suite biocide filter for healthier and cleaner air in indoor environments
Enhanced performance with 4-row coil
Consumption reduced by 50% with EC motor
Continuous fan speed regulation

Fan coils with EC motor

Description

Construction features

• Heat exchanger: with finned coil with left side connections reversible to the right.
• Centrifugal fan with an inverter controlled electronic brushless motor and continuous speed adjustment.
• Cabinet version structure: covering cabinet in pre-painted sheet steel, RAL9003, complete with a regenerable filter, ABS polymer grilles and a natural condensate drain pan.
• Recessed version structure: in galvanised sheet steel, complete with a natural condensate drain pan and regenerable filter.

Versions

• MVP - Vertical unit with cabinet equipped with lower air inlet and upper delivery for wall mounting installation or with feet on the ground.
• MVT - Vertical unit with cabinet equipped with front air inlet and upper delivery for floor installation.
• MXP - Horizontal/vertical unit with cabinet, equipped with lower air inlet and upper delivery, for ceiling installation, wall mounted or with feet on the ground.
• MXT - Horizontal/vertical unit with cabinet, equipped with front air inlet and upper delivery, for ceiling or floor installation.
• IVP - Recessed vertical unit equipped with lower air inlet and upper delivery for wall mounting installation.
• IVF - Recessed vertical unit equipped with lower air inlet and front delivery for wall mounting installation.
• IXP - Horizontal/vertical unit equipped with lower air inlet and upper delivery for false ceiling or recessed wall installation.

Construction set-ups

Type of unit
2T - Single main coil.
4T - Double main coil and additional.

ACCESSORIES

➔❖ Additional water heating coil for 4-pipe systems.
➔❖ Electrical resistance.
➔❖ 2 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 3 -way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ 4-way ON/OFF electrovalves for 4-pipe systems with single main coil.
➔❖ Auxiliary condensate drain pan.
➔❖ Air'Suite biocide filter.
❖ Electrical box for connection terminal block.
❖ Air inlet flange: Ø10cm or Ø12cm.
➔ Manual damper.
➔ Motorised damper.
➔ Back in view.
➔ Rear closing panel.
➔ Rear closing panel with grille and filter.
➔ Support feet with pipe cover.
➔ Flanged frame for duct connection.
➔ Frame with Air'Suite biocide filter (G2) that can be extracted in any direction.
➔ Delivery straight fitting.
➔ 90° delivery and inlet fitting.
➔ Telescopic outlet/inlet fitting.
➔ Inlet grille with filter.
➔ Delivery grille.
➔ Formwork for recessed wall or false ceiling installation.
➔ Aesthetic panel for wall mounted formwork, with air delivery and return grille.
➔ Aesthetic panel for formwork, with air inlet grille.
➔ Delivery nozzle made of aluminium, with a double row of adjustable fins.
➔ Anti-vibration fitting for delivery/inlet duct connection.
➔ Intake/outlet plenum with round nozzles.

CONTROLS

STANDARD controls
For wall mounting installation
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.

Advanced LIT-TOUCH controls

➔ Flush LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ Wall mounted LIT-Touch remote control and receiver with air temperature probe and operation LED.
➔❖ LIT-Touch control with air temperature probe for on board installation.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with a minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔❖ Additional board with 2 digital outputs that can be configured.
➔❖ On board air temperature probe.
➔❖ RS485 serial board for serial communication with other devices (Modbus RTU protocol).

Key: ❖ Factory fitted
➔ Supplied separately

Technical data

YARDY-I EV3 MVP-MVT-MXP-MXT-IVP-IVF-IXP 20 24 30 34 45 48 60 74 80 88
Total cooling capacity [EN1397] MAX kW E 1,86 2,24 2,97 3,37 4,11 4,6 6,28 7,33 7,94 8,4
MED kW E 1,44 1,68 2,33 2,75 3,05 3,49 4,6 5,24 5,87 6,32
MIN kW E 0,75 0,8 1,08 1,34 1,53 1,73 1,78 2,1 2,1 2,25
Heating capacity (45°C) [EN1397] MAX kW E 2,1 2,18 3,27 3,41 4,47 4,65 7,13 7,41 9,67 10,07
MED kW E 1,48 1,57 2,52 2,6 3,13 3,27 5,12 5,31 7,15 7,43
MIN kW E 0,77 0,81 1,2 1,26 1,5 1,57 1,88 1,94 2,63 2,74
Heating capacity (50°C) MAX kW E 2,47 2,6 3,87 4,07 5,3 5,54 8,38 8,81 11,29 11,77
MED kW E 1,77 1,88 2,99 3,14 3,74 3,93 6,07 6,37 8,39 8,75
MIN kW E 0,92 0,97 1,42 1,52 1,81 1,9 2,25 2,36 3,07 3,22
Heating capacity (70°C) [EN1397] MAX kW 4,2 4,36 6,56 6,85 8,96 9,31 14,28 14,86 19,35 20,14
MED kW 2,98 3,14 5,06 5,26 6,28 6,56 10,3 10,77 14,35 14,91
MIN kW 1,56 1,64 2,44 2,56 3,06 3,19 3,87 3,98 5,37 5,6
Heating capacity of additional coil (65°C) [EN1397] MAX kW E 1,95 2,08 2,94 2,8 3,36 3,2 5,64 5,37 6,5 6,17
MED kW E 1,66 1,6 2,34 2,22 2,84 2,7 4,67 4,45 5,39 5,14
MIN kW E 0,87 0,83 1,3 1,23 1,53 1,46 2,17 2,06 2,51 2,4
Heating capacity of additional coil (70°C) [EN1397] MAX kW E 2,21 2,36 3,33 3,17 3,83 3,64 6,38 6,08 7,37 6,98
MED kW E 1,92 1,84 2,65 2,52 3,3 3,15 5,3 5,04 6,12 5,83
MIN kW E 1,01 0,96 1,48 1,41 1,79 1,7 2,5 2,38 2,9 2,76
Air flow speed MAX m³/h 331 331 523 523 645 645 1235 1235 1503 1458
MED m³/h 230 230 400 400 450 450 780 780 965 965
MIN m³/h 97 97 167 167 198 198 256 256 300 300
Sound power MAX dB(A) E 48 48 50 50 51 51 62 62 66 66
MED dB(A) E 40 40 43 43 42 42 50 50 56 56
MIN dB(A) E 29 29 29 29 29 29 30 30 32 32
Sound pressure MAX dB(A) 39 39 41 41 42 42 53 53 57 57
MED dB(A) 31 31 34 34 33 33 41 41 47 47
MIN dB(A) 20 20 20 20 20 20 21 21 23 23
Absorbed power MAX W E 23 25 26 28 39 42 89 95 136 146
MED W E 13 14 15 16 14 15 28 30 52 56
MIN W E 6 6 6 6 7 8 7 7 9 10
Electrical supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
DIMENSIONS AND WEIGHT 20 24 30 34 45 48 60 74 80 88
L – MXP-MXT-MVP-MVT width mm 800 800 1000 1000 1200 1200 1500 1500 1500 1500
L – IVP-IXP-IVF width mm 550 550 750 750 950 950 1250 1250 1250 1250
H – MXP-MXT-MVP-MVT height mm 570 570 570 570 570 570 570 570 570 570
H – IVP-IXP-IVF height mm 545 545 545 545 545 545 545 545 545 545
MVP-MVT-MXP-MXT Feet height mm 100 100 100 100 100 100 100 100 100 100
P – MXP-MXT-MVP-MVT Depth mm 220 220 220 220 220 220 220 220 220 220
P – IVP-IXP-IVF Depth mm 212 212 212 212 212 212 212 212 212 212
MXP-MXT-MVP-MVT Weight kg 20 20,5 21 22 28 29 35 36 37 38
IVP-IXP-IVF Weight kg 16,5 17 20,5 21,5 25,5 27 34,5 35,5 36,5 37,5
  • Data at the following conditions:
  • Air: 27°C D.B.; 19°C W.B. – Water: 7/12°C.
  • Air: 20°C – Water: 45/40°C.
  • Air: 20°C – Water: 50°C, flow rate as in cooling.
  • Air: 20°C – Water: 70/60°C.
  • Air: 20°C – Water: 65/55°C.
  • For room volume equal to 100 m³ and reverberation time = 0.5 sec.
  • E Eurovent certified performance.
  • Performance refers to the motor’s input signal: 10V – 6V – 1V at MAX – MED – MIN speed.
  • YARDY-I EV3 24 – 34 – 48 – 74 – 88 with oversized 4-row coil.
  • For the selection with Air’Suite filter, refer to the UP-TO-DATE selection Software.

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Format: tif
Format: tif
Format: tif
Format: tif
Format: tif
Format: tif
Format: tif
Format: tif
Format: tif
Request information about this product