FAN COILS

Ductable terminals

YARDY-HP
Cooling capacity 7,0÷19,8 kW
Heating capacity 9,9÷29,6 kW

Ductable terminals for recessed horizontal or vertical installation.

Features

Key features

Air'Suite biocide filter for healthier and cleaner air in indoor environments
New touch controls
Horizontal and vertical installation
Pan removable from below for cleaning
Hydraulic and electric connections on the same side.
Set up with 3, 4, 5-row coil

Ductable terminals

Description

Construction features

• Structure: self-supporting, in galvanised sheet steel for horizontal installation in a false ceiling or vertical recessed wall installation, complete with a natural condensate drain pan, flanges to fit to the inlet/delivery duct. Pan is removable from below.
Filter supplied separately from the unit.
• Finned coil heat exchanger, removable from below, with connections on the left, reversible to the right directly on site.
• Electrical connection box: on the left, on the same side as the hydraulic connections, reversible to the right directly on site.
• Double intake centrifugal fan with directly coupled 3-speed motor.
Fan unit is removable from below.

Versions

• CXP - Recessed unit for horizontal or vertical installation (with lower return to upper delivery).
Number of rows
• 3 Rows - Unit with 3-row coil; for recessed horizontal/vertical installation.
• 4 Rows - Unit with 4-row coil; for recessed horizontal/vertical installation.
• 5 Rows - Unit with 5-row coil (only models 250, 300); for recessed horizontal/vertical installation.

Construction set-ups

Type of unit
2T - Single main coil
4T - Double main coil and additional

ACCESSORIES

➔❖ Additional water heating coil (1 row) for [4T-KBAA] 4-pipe systems - only for 3R units with a 3-row coil.
➔ External plenum with additional water heating coil for 4-pipe systems [PBAB].
➔❖2-way ON/OFF electrovalves for 2 and 4-pipe systems.

➔❖3-way ON/OFF electrovalves for 2 and 4-pipe systems.
➔❖ Auxiliary condensate drain pan.
➔ Frame with filter that can be extracted in any direction (G1 or G3).
➔ Frame with Air'Suite biocide filter (G2) that can be extracted in any direction.
➔ Straight delivery and inlet fitting.
➔ 90° delivery and inlet fitting.
➔ Flange for duct connection.
➔ Anti-vibration fitting for connection to the inlet/delivery duct.
➔ Panel with round nozzles to be connected to the delivery/inlet fittings.

CONTROLS

STANDARD controls
For wall mounting installation
➔ Panel with speed and summer/winter switch.
➔ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve control and electrical resistance.
➔ Electronic panel with automatic summer/winter switching for 2-pipe systems.
➔ Electronic panel with automatic summer/winter switching and automatic speed adjustment for 2-pipe systems with electrical resistance or 4-pipe systems.
➔ Air probe with remote control option.
➔ Interface board to control up to 4 fan coils (models 100-150-200 only, for on board installation).

Advanced LIT-TOUCH controls

➔ Flush LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ Wall mounted LIT-Touch remote control and receiver with air temperature probe and operation LED.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔❖ Additional board with 2 digital outputs that can be configured.
➔❖ On board air temperature probe.
➔❖ RS485 serial board for serial communication with other devices (Modbus RTU protocol).

Key: ❖ Factory fitted
➔ Supplied separately

Technical data

YARDY HP CXP 100 150 200 250 300
Total cooling capacity [EN1397] 3R   MAX kW 6,96 8,13 9,75 12,85 14,42
3R   MED kW 6,45 6,49 7,19 9,32 11,15
3R   MIN kW 5,33 6,19 6,43 6,87 9,82
Heating capacity (45°C) [EN1397] 3R   MAX kW 8,38 10,23 12,58 17,03 19,51
3R   MED kW 7,61 7,85 8,99 11,62 14,71
3R   MIN kW 6,08 7,34 7,77 8,09 12,49
Heating capacity (50°C) 3R   MAX kW 9,85 12,09 14,85 20,13 23,11
3R   MED kW 9 9 10,41 13,64 17,01
3R   MIN kW 7,27 8,53 9,11 9,64 14,6
Total cooling capacity [EN1397] 4R   MAX kW 8,22 9,28 11,04 15,88 18
4R   MED kW 7,53 8,09 8,95 11,79 14,31
4R   MIN kW 6,31 7,61 8,14 8,36 12,52
Heating capacity (45°C) [EN1397] 4R   MAX kW 9,32 10,93 13,34 19,59 22,62
4R   MED kW 8,35 9,09 10,33 13,9 17,73
4R   MIN kW 6,83 8,39 9,1 9,27 14,85
Heating capacity (50°C) 4R   MAX kW 11,01 12,88 15,73 23,36 27,12
4R   MED kW 9,93 10,58 12,11 16,55 20,9
4R   MIN kW 8,18 9,87 10,79 11,15 17,67
Total cooling capacity [EN1397] 5R   MAX kW - - - 18,04 19,75
5R   MED kW - - - 12,78 16,32
5R   MIN kW - - - 8,91 14,04
Heating capacity (45°C) [EN1397] 5R   MAX kW - - - 21,83 24,62
5R   MED kW - - - 14,42 18,69
5R   MIN kW - - - 9,37 16,19
Heating capacity (50°C) 5R   MAX kW - - - 26,23 29,62
5R   MED kW - - - 17,26 22,23
5R   MIN kW - - - 11,47 19,24
Heating capacity of additional coil (65°C) [EN1397] 4T -KBAA  MAX kW 6,11 6,23 8,63 9,88 10,76
Heating capacity of additional coil (70°C) [EN1397] 4T -KBAA  MAX kW 6,89 7,03 9,73 11,12 12,11
Heating capacity of additional coil (65°C) [EN1397] PBAB   MAX kW 11,61 12,74 14,87 20,72 22,77
Heating capacity of additional coil (70°C) [EN1397] PBAB   MAX kW 13,1 14,39 16,78 23,36 25,67
Air flow rate/Speed static pressure (3R) MAX m³/h / Pa 1.552 / 60 1.840 / 62 2.339 / 60 3.312 / 60 3.875 / 59
MED m³/h / Pa 1.370 / 50 1.620 / 50 1.717 / 50 2.189 / 50 3.075 / 50
MIN m³/h / Pa 1.013 / 35 1.432 / 35 1.414 / 35 1.329 / 35 2.415 / 35
Delivery sound power (3R) MAX dB(A) 61 62 62 63 68
MED dB(A) 59 61 60 59 64
MIN dB(A) 56 59 57 55 61
Speed sound pressure (3R) MAX dB(A) 47 48 48 49 54
MED dB(A) 45 47 46 45 50
MIN dB(A) 42 45 43 41 47
Nominal spd absorbed power MAX 3R W 200 245 380 680 800
4R W 190 230 330 670 750
5R W - - - 660 750
Maximum absorbed power (0 Pa) 3R W 280 300 500 850 900
Electrical supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
DIMENSIONS AND WEIGHTS 100 150 200 250 300
L – Width mm 1295 1295 1295 1295 1295
H – Height mm 250 250 285 335 335
P – YARDY HP Depth mm 555 555 670 720 720
P – PBAB Depth mm 200 200 200 200 200
YARDY HP Weight kg 38 38 46 57 57
  • Data at the following conditions:
  • Air: 27°C D.B.; 19°C W.B. – Water: 7/12°C.
  • Air: 20°C – Water: 45/40°C.
  • Air: 20°C – Water: 50°C, flow rate as in cooling.
  • Air: 20°C – Water: 70/60°C.
  • Air: 20°C – Water: 65/55°C.
  • 3-row coil (3R) without filter.
  • With G3 filter at the conditions specified in point 6 according to EN16583
  • At 2 m from the air outflow point with directionality factor 2 and G3 filter.

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.