Web code: UTNR3
AIR HANDLING TERMINAL UNITS AND HEAT RECOVERY UNITS

Heat recovery unit

UTNR-A Platinum
Air flow rate 400÷4.700 m³/h

Fresh air terminal units with counterflow opposing flow static heat recovery.

Features

Key features

Horizontal or Vertical Version
Very high efficiency heat recovery Eurovent Certificate
Multi-speed or Brushless EC fans
F7 and M5 high efficiency filters
Double sandwich wall with high insulation capacity

Heat recovery unit

Description

Construction features

• Recovery unit: very high yield static type with aluminium plates with back-current flows with close step. Extraction of side exchange pack from top or bottom depending on models and versions
• Fans: Outdoor air intake and forward blade dual intake centrifugal exhaust type with a directly coupled electric motor; optionally, EC Brushless technology high efficiency electric motors. The fan unit is installed on anti-vibration mountings to prevent vibrations being transmitted to the structure.
• Structure: frame made with extruded aluminium profile with preloaded nylon joints. Sandwich buffer panels, 23 mm thick, made with galvanised sheet steel on the inside and pre-painted on the outside with thermal and acoustic insulation made of injected polyurethane, with a density of 45 kg/m3.
• Filtering section: filtration sections made of compact cell filters with low pressure drop polypropylene media, removable from the side, with ISO 16890 ePM1 55% efficiency class ( F7 EN 779) in fresh flow and ISO 16890 ePM10 55% ( M5 EN 779) in exhaust flow.
• Factory-installed dirty filter differential pressure switches
• Condensate drain pan made of galvanised sheet steel with condensate drain connection from the bottom.
• Integrated free cooling or thawing by-pass system. Thanks to the presence of a motorised damper next to the heat recovery, a bypass system can be created to manage freecooling or thawing depending on thermo-hygrometric needs or conventions

Versions

• UTNR-A/O PLATINUM - Recovery unit with opposing flow heat exchanger, horizontal installation and with standard multi-speed fans
• UTNRE-A/O PLATINUM - Recovery unit with opposing flow heat exchanger, horizontal installation and with Brushless EC fans that reduce power consumption for ventilation at equal performance.
• UTNR-A/V PLATINUM - Recovery unit with opposing flow heat exchanger, installed vertically and with standard multi-speed fans
• UTNRE-A/V PLATINUM - Recovery unit with opposing flow heat exchanger, installed vertically and with Brushless EC fans that reduce power consumption for ventilation at equal performance.

Available orientation
• 01 - Right-hand connections
• 02 - Left-hand connections
The selected orientation must be specified to process the job order.

Installation
• EXT- Outdoor installation including rain cover, 80 mm-high base and an outdoor electrical box (the kit does not include the roof for any additional accessory modules)

Factory fitted accessories

• BER - PRE-POST - Pre-heating electrical resistance (no frost function) installed inside, complete with filament-type safety thermostats and control relays to contain pressure drops.
• BA - Internal hot water reheating coil.
• BAATG - Antifreeze thermostat installed downstream of the water reheating coil.
• ERF7-F7 efficiency return filter

Separately supplied accessories

• KSBFR - Section containing hot/cold water coil to reheat or recool, placed outside the machine in front of the intake vent. Includes stainless steel condensate drain pan with drain connection from the bottom.
• KSBFR + ATG - Hot/cold water coil section with mounted antifreeze thermostat.
• KSRE - Regulation damper set up for servo-control, consisting of a galvanised sheet steel frame with adjustable fins.
• KSSC - Duct silencer with rectangular baffles in mineral wool covered with a protective film of glass fibre and micro-stretched sheet metal.
• KRMS - Sections with three dampers for air mixing and recirculation (only for horizontal installation).
• KSPC - 4 circular connections

Controls

• KCV2 - Speed selector for wall mounting installation, to select from 3 speeds: Off/heating/cooling switch; 3-speed switch; 230V power supply.
• PCUS – composed from the control unit on board of the unit + WALL LCD display , suitable for controlling units with 3-speed fans or EC Brushless
Functionality: control of the winter/summer ambient temperature, management of: water battery and antifreeze thermostat (ON/OFF or modulating valve control), electrical resistance of preheating and/or post-heating, air dampers, freecooling of heat recovery, air filter pressure switches, CO2 or Humidity sensor for automatic modulation of EC fans, integrated clock for time slot program.
• PCUSM- same functionality as PCUS card with Modbus RTU connection port
• FULL CONTROL- for a description of these controls, please refer to the relevant page

Technical data

UTNR-A PLATINUM MODEL 40 75 100 150 200 320 400 500
Outdoor air filters F7 F7 F7 F7 F7 F7 F7 F7
Return air filters M5 M5 M5 M5 M5 M5 M5 M5
TECHNICAL SPECIFICATIONS
Nominal air flow rate m³/h 400 750 1000 1500 2050 3200 3800 4700
STANDARD FANS
Motor type AC AC AC AC AC AC n.d. n.d.
Nominal available static pressure Pa 160 120 180 160 120 180 n.d. n.d.
Max. available static pressure Pa 160 120 180 160 120 180 n.d. n.d.
Specific fan power (SFP) W/(m³/s) 740 934 1105 1102 1078 1054 n.d. n.d.
Sound power level dB(A) 58 61 61 64 64 68 n.d. n.d.
Speed No./Adjustment Type 3 3 3 3 3 3 n.d. n.d.
Electrical supply V-ph-Hz 230-1-50 230-1-50 230-1-50/60 230-1-50/60 230-1-50/60 230-1-50/60 n.d. n.d.
BRUSHLESS EC FANS
Motor type EC EC EC EC EC EC EC EC
Nominal available static pressure Pa 160 120 180 160 120 180 200 200
Max. available static pressure Pa 340 210 520 500 540 375 330 200
Specific fan power (SFP) W/(m³/s) 705 742 1059 1048 898 1040 949 935
Sound power level dB(A) 57 60 59 61 59 64 66 68
Speed No./Adjustment Type 0-10 V 0-10 V 0-10 V 0-10 V 0-10 V 0-10 V 0-10 V 0-10 V
Electrical supply V-ph-Hz 230-1-50 230-1-50 230-1-50/60 230-1-50/60 230-1-50/60 230-1-50/60 230-1-50/60 230-1-50/60
COUNTERFLOW HEAT RECOVERY
Winter Efficiency % 83,6 82,9 81,6 83,3 83,7 86,8 84,1 84,2
Summer Efficiency % 75,5 75,9 74,5 75,1 75,6 78 75 75,1
Efficiency Regulation EC 1253/2014 % 75,9 76,4 75 75,6 76 76,3 75,5 75,6
OPERATING LIMITS
Outdoor air humidity/temperature limit °C/% -5
Outdoor air humidity/temperature limit with KRMS accessory °C/% -15
Indoor air humidity/temperature limit °C/% +10
DIMENSIONS AND WEIGHTS 40 75 100 150 200 320 400 500
HORIZONTAL vers. length mm 1480 1940 1940 2200 2200 2500 2500 2500
HORIZONTAL vers. height mm 380 480 480 550 550 680 680 680
HORIZONTAL vers. depth mm 800 990 990 1000 1400 1400 1400 1700
HORIZONTAL vers. weight kg 90 140 150 170 200 230 260 300
VERTICAL vers. length mm 1480 1940 1940 2200 2200 2500 2500 2500
VERTICAL vers. depth mm 420 520 520 520 720 720 720 720
VERTICAL vers. height mm 830 1070 1070 1080 1480 1480 1480 1780
VERTICAL vers. weight kg 90 150 160 180 220 250 280 330
Condensate drain inch 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″
  • Data at the following conditions:
  • Values referring to the nominal air flow rate considering the pressure drops of the heat recovery and the F7 filter.
  • Values referring to the nominal air flow rate and Nominal available static pressure.
  • Radiated sound power level from casing.
  • Outdoor air T: -5°C, 80% UR; Ambient air T: 20°C, 50% UR.
  • Outdoor air T: 32°C, 50% UR; Amb. air T: 26°C, 50% UR.
  • Dry nominal conditions, measured according to En 308 in balanced flows. Outdoor air 5°C D.B.; Ambient air 25°C D.B.
  • Outdoor air T: 32°C, 50% UR; Amb. air T: 26°C, 50% UR.
  • Dry nominal conditions, measured according to En 308 in balanced flows. Outdoor air 5°C D.B.; Ambient air 25°C D.B.

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.