WinFLOW ECO EXP WinFLOW EXP
TXHET 4185÷4395EXPsystems - Polyvalent ecological water-cooled system. Series with scroll hermetic compressors and R454B or R410A refrigerant gas.
Key features
Multi-purpose units with TER up to 7,5
Efficient and eco-friendly range in R454B
Applications with well water, water mains, geothermal probes or dry cooler
Extended operating limits
Touch interface (optional)
Integrated MASTER/SLAVE control
Description
Construction features
• Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater.
• Primary side (user), secondary (recovery) and disposal side heat exchanger (well, mains, geothermal probes or dry cooler): with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- compressor circuit breaker switches;
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- 0-10V analogue signal for condensing/evaporating control performed by external device;
- control of Variable Primary Flow (VPF_R).
Versions
• T - High efficiency version
Models
- TXHETU: EXPsystems units with R454B gas.
- TXHETY: EXPsystems units with R410A gas.
Factory fitted accessories
• Recovery side VPF_R control.
• Power factor correction capacitors (cosφ > 0.94).
• Soft-starter.
• Energy parameter measuring device.
• Cooling circuit outlet and intake valves (TXHETY)
• Cooling circuit outlet valves (TXHETU).
• Refrigerant leak detector.
• Forced limit of power consumption.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Technical compartment soundproofing.
• Compressor soundproof enclosures
• Control of min/max power supply voltage.
• Low temperature water production.
• Digital input for double set-point.
• 4-20mA analogue signal for shifting set-point.
• Antifreeze heaters for heat exchangers and electrical panel.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7'' display.
• Set-up for outdoor installation.
• Anti-vibration mounts.
Separately supplied accessories
• 3-way modulating condensing control valve.
• 2-way modulating condensing control valve.
• Outdoor air temperature probe for set-point compensation.
• Water filter.
• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.
Technical data
TXHETU MODEL | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
COOLING OPERATIONS (AUTOMATIC 1 MODE) | |||||||||||
❶ | Nominal cooling capacity | kW | 180 | 206,7 | 232,4 | 259,3 | 286,4 | 324,8 | 365,2 | ||
❶ | Absorbed power | kW | 40,3 | 48,3 | 55,2 | 61,2 | 67,2 | 76,2 | 86,5 | ||
❶ | E.E.R. | 4,47 | 4,28 | 4,21 | 4,24 | 4,26 | 4,26 | 4,22 | |||
COOLING OPERATIONS + TOTAL RECOVERY (AUTOMATIC 2 MODE) | |||||||||||
❷ | Nominal cooling capacity | kW | 156,5 | 181,9 | 206,8 | 232,4 | 259,1 | 298,2 | 330,7 | ||
❷ | Recovery heating capacity | kW | 202,7 | 237,2 | 270,6 | 302,2 | 335,5 | 384,7 | 428,9 | ||
❷ | T.E.R. | 7,45 | 7,23 | 7,16 | 7,29 | 7,38 | 7,5 | 7,32 | |||
HEATING OPERATIONS (MODE SELECT 1-2 AUTOMATIC 3) | |||||||||||
❸ | Nominal heating capacity | kW | 200,1 | 234,6 | 267,2 | 299 | 332,3 | 380,2 | 424,8 | ||
❸ | Total absorbed power | kW | 49,8 | 60 | 68,9 | 76,1 | 83,9 | 94,8 | 108,4 | ||
❸ | C.O.P. | 4,02 | 3,91 | 3,88 | 3,93 | 3,96 | 4,01 | 3,92 | |||
TXHETU MODEL | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
❹ | Sound pressure | dB(A) | 47 | 47 | 48 | 49 | 51 | 52 | 53 | ||
❺ | Sound power | dB(A) | 79 | 79 | 80 | 81 | 83 | 84 | 85 | ||
❺ | Sound power with soundproofing set-up | dB(A) | 76,5 | 76,5 | 77,5 | 78,5 | 80,5 | 81,5 | 82,5 | ||
Scroll compressor/steps | no. | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | |||
Circuits | no. | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |||
Electrical supply | V-ph-Hz | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | |||
DIMENSIONS AND WEIGHTS | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
L – Width | mm | 2510 | 2510 | 2510 | 2510 | 2510 | 2510 | 2510 | |||
H – Height | mm | 1860 | 1860 | 1860 | 1860 | 1860 | 1860 | 1860 | |||
P – Depth | mm | 870 | 870 | 870 | 870 | 870 | 870 | 870 | |||
❻ | Weight | kg | 1205 | 1315 | 1455 | 1500 | 1520 | 1675 | 1770 | ||
SEASONAL ENERGY PERFORMANCE | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
TXHETU MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||||
① | Pdesignc (EN 14825) | kW | - | - | - | - | - | 324,8 | 365,2 | ||
① | SEER (EN 14825) | - | - | - | - | - | 6,29 | 6,3 | |||
② | ηs,c | % | - | - | - | - | - | 249 | 249 | ||
TXHETU MODEL SEASONAL PERFORMANCE IN HEATING MODE | |||||||||||
③ | Pdesignh (EN 14825) | kW | 239 | 280 | 318 | 356 | 396 | - | - | ||
③ | SCOP (EN 14825) | 6,79 | 6,66 | 6,54 | 6,47 | 6,48 | - | - | |||
④ | ηs | % | 263 | 258 | 254 | 251 | 251 | - | - | ||
TXHETY MODEL | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
COOLING OPERATIONS (AUTOMATIC 1 MODE) | |||||||||||
❶ | Nominal cooling capacity | kW | 184,6 | 211,6 | 238,4 | 266,2 | 293,9 | 333,1 | 373,8 | ||
❶ | Absorbed power | kW | 42,1 | 50,6 | 57,7 | 64,1 | 70,5 | 79,9 | 90,5 | ||
❶ | E.E.R. | 4,38 | 4,18 | 4,13 | 4,15 | 4,17 | 4,17 | 4,13 | |||
COOLING OPERATIONS + TOTAL RECOVERY (AUTOMATIC 2 MODE) | |||||||||||
❷ | Nominal cooling capacity | kW | 159,7 | 185,4 | 211 | 236,8 | 263,5 | 303,7 | 337,1 | ||
❷ | Recovery heating capacity | kW | 208,2 | 243,2 | 277,7 | 310 | 343,4 | 394,3 | 439,9 | ||
❷ | T.E.R. | 7,27 | 7,07 | 7 | 7,11 | 7,19 | 7,32 | 7,15 | |||
HEATING OPERATIONS (MODE SELECT 1-2 AUTOMATIC 3) | |||||||||||
❸ | Nominal heating capacity | kW | 205,5 | 240,6 | 274,3 | 306,7 | 340,2 | 389,7 | 435,7 | ||
❸ | Total absorbed power | kW | 52,2 | 62,8 | 72,2 | 79,7 | 87,9 | 99,2 | 113,5 | ||
❸ | C.O.P. | 3,94 | 3,83 | 3,8 | 3,85 | 3,87 | 3,93 | 3,84 | |||
TXHETY MODEL | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
❹ | Sound pressure | dB(A) | 47 | 47 | 48 | 49 | 51 | 52 | 53 | ||
❺ | Sound power | dB(A) | 79 | 79 | 80 | 81 | 83 | 84 | 85 | ||
❺ | Sound power with soundproofing set-up | dB(A) | 76,5 | 76,5 | 77,5 | 78,5 | 80,5 | 81,5 | 82,5 | ||
Scroll compressor/steps | no. | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | |||
Circuits | no. | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |||
Electrical supply | V-ph-Hz | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | |||
DIMENSIONS AND WEIGHTS | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
L – Width | mm | 2510 | 2510 | 2510 | 2510 | 2510 | 2510 | 2510 | |||
H – Height | mm | 1860 | 1860 | 1860 | 1860 | 1860 | 1860 | 1860 | |||
P – Depth | mm | 870 | 870 | 870 | 870 | 870 | 870 | 870 | |||
❻ | Weight | kg | 1205 | 1315 | 1455 | 1500 | 1520 | 1675 | 1770 | ||
SEASONAL ENERGY PERFORMANCE | 4185 | 4210 | 4240 | 4275 | 4305 | 4350 | 4395 | ||||
TXHETY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||||
① | Pdesignc (EN 14825) | kW | - | - | - | - | 293,9 | 333,1 | 373,8 | ||
① | SEER (EN 14825) | - | - | - | - | 6,21 | 6,2 | 6,23 | |||
② | ηs,c | % | - | - | - | - | 245 | 245 | 246 | ||
TXHETY MODEL SEASONAL PERFORMANCE IN HEATING MODE | |||||||||||
③ | Pdesignh (EN 14825) | kW | 246 | 287 | 327 | 365 | - | - | - | ||
③ | SCOP (EN 14825) | 6,74 | 6,58 | 6,47 | 6,44 | - | - | - | |||
④ | ηs | % | 262 | 255 | 251 | 249 | - | - | - | ||
- Data at the following conditions:
- ❶ Chilled water (user): 12/7℃ – Condenser water (disposal unit-source): 30/35℃
- ❷ Chilled water (user) outlet: 7℃, nominal flow rate – Condenser water outlet (recovery unit): 45℃, nominal flow rate.
- ❸ Evaporator water (disposal-source): 10/7℃ – Hot water (utility): 40/45℃.
- ❹ In open field (Q = 2) at 10 m from the unit.
- ❺ Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
- ❻ Weight refers to the unit empty with soundproofing.
- Performance according to EN 14511.
- T.E.R.: Total efficiency ratio
- ① Low temperature application (7°C)
- ② Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
- ③ In Average climatic conditions, low temperature application (35℃)
- ④ Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Images
Request information about this product
Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.