New
Web code: UPX07
EXP Multi-purpose Systems

UniPACK-P EXP

TXAEP 251÷4160
Cooling capacity 47÷158,8 kW
Heating capacity 49,1÷161,1 kW

EXPsystems – Air cooled multi-purpose ecological system with axial fans.
Range with scroll hermetic compressors and R290 refrigerant gas.

Features

Key features


Efficient and eco-friendly range in R290

Temperature of the produced water up to 72°C

TER up to 7,74

Extended operating limits

Integrated MASTER/SLAVE control


UniPACK-P EXP

Description

Construction features

• Compressor: hermetic rotary, scroll type, complete with thermal protection and casing heater.
• 2-4 capacity steps with high efficiency at part loads.
• Main and secondary heat exchangers: crossed flow stainless steel plate exchangers, complete with antifreeze heater, closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: finned coil with copper pipes and aluminium fins.
• Fan: external rotor axial type electric fans equipped with internal thermal protection and accident protection grilles. The electric fans, based on the sizes, are EC fans or fitted with a proportional electronic device for continuous adjustment of the rotation speed.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• Refrigerant leak detector.
• Coil protection nets.
• The unit is also complete with:
- compressor and fan circuit breaker switches;
- electronic expansion valve;
- display of cooling circuit high/low pressure;
- master/slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version.
• Q - Super silenced version complete with compressor technical compartment soundproofing and reduced speed fans.

Models

• TXAETP: EXPsystems unit.
• TXAEQP: super silenced EXPsystems unit.

Factory fitted accessories

• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• Inverter pump control for unit start-up.
• Recovery side VPF_R control.
• Desuperheater.
• Condensing control with fans with EC motor (standard in sizes 251-280).
• Condensing control with over-pressure fans (T version only)
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Soft starter.
• Compressor technical compartment soundproofing.
• Compressor soundproof enclosures.
• Double safety valves.
• Buffer panels.
• Copper/copper, pre-painted copper/aluminium or with hydrophilic treatment coils.
• Control of min/max power supply voltage and backup battery.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Contacts for Smart Grid integration and photovoltaic system.
• Electrical panel resistance, base, electric pumps and heat exchangers for heat recovery, if any.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7” display.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TXAETP MODEL 251 260 270 280 4100 4110 4120 4130 4140 4150 4160
COOLING OPERATIONS (AUTOMATIC 1 MODE)
Nominal cooling capacity kW 48,5 58,4 68,4 79,4 95,9 104,9 117,9 126,9 135,9 147,9 158,8
Absorbed power kW 16,3 19,8 22,9 26,7 32,7 36,3 40,9 43 46,4 51 54,4
E.E.R. 2,98 2,95 2,99 2,97 2,93 2,89 2,88 2,95 2,93 2,9 2,92
COOLING OPERATIONS + TOTAL RECOVERY (AUTOMATIC 2 MODE)
Nominal cooling capacity kW 48,9 59,2 69,7 81 97,9 107 120,9 128,7 137,8 150,6 162,1
Recovery heating capacity kW 63,2 76,3 90,3 104,4 126,5 138,5 155,7 166,6 178,6 194,8 208,9
T.E.R. 7,57 7,67 7,5 7,67 7,57 7,52 7,7 7,53 7,49 7,56 7,67
HEATING OPERATIONS (MODE SELECT 1-2 AUTOMATIC 3)
Nominal heating capacity kW 50,1 59,1 71,1 80,1 102,1 110,1 120,1 134,1 143,2 153,1 161,1
Absorbed power kW 15,6 18,3 21,8 24,5 31,8 34,4 37,4 41,8 44,6 47,7 50,2
C.O.P. 3,21 3,23 3,26 3,27 3,21 3,2 3,21 3,21 3,21 3,21 3,21
TXAEQP MODEL 251 260 270 280 4100 4110 4120 4130 4140 4150 4160
COOLING OPERATIONS (AUTOMATIC 1 MODE)
Nominal cooling capacity kW 47 56,4 66,4 76,9 92,9 101,9 112,9 123,9 131,9 143,9 152,9
Absorbed power kW 16,4 19,9 23 26,9 33,5 37,2 42,1 43,6 47,1 51,9 55,8
E.E.R. 2,87 2,83 2,89 2,86 2,77 2,74 2,68 2,84 2,8 2,77 2,74
COOLING OPERATIONS + TOTAL RECOVERY (AUTOMATIC 2 MODE)
Nominal cooling capacity kW 49,1 59,4 69,9 81,3 98,2 107,3 121,4 129 138,2 151,1 162,7
Recovery heating capacity kW 63,4 76,4 90,5 104,7 126,8 138,8 156,1 166,9 178,9 195,2 209,5
T.E.R. 7,61 7,7 7,52 7,7 7,6 7,55 7,74 7,55 7,52 7,6 7,7
HEATING OPERATIONS (MODE SELECT 1-2 AUTOMATIC 3)
Nominal heating capacity kW 49 58,1 70,1 79,1 100,1 108,1 118,1 132,1 140,1 149,1 158,1
Absorbed power kW 15,1 17,7 21 23,8 31,2 33,8 36,8 41 43,5 46,6 49,3
C.O.P. 3,25 3,28 3,34 3,33 3,21 3,2 3,21 3,22 3,22 3,2 3,21
TXAETP-TXAEQP MODEL 251 260 270 280 4100 4110 4120 4130 4140 4150 4160
TXAETP sound pressure dB(A) 49 49 51 52 53 53 54 55 55 55 56
TXAEQP sound pressure dB(A) 44 45 46 47 48 48 49 50 50 50 51
TXAETP sound power dB(A) 81 81 83 84 85 85 86 87 87 87 88
TXAEQP sound power dB(A) 76 76 78 79 80 80 81 82 82 82 83
Scroll compressors/steps no. 2/2 2/2 2/2 2/2 4/4 4/4 4/4 4/4 4/4 4/4 4/4
Circuits no. 2 2 2 2 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 251 260 270 280 4100 4110 4120 4130 4140 4150 4160
L – Width mm 2550 2550 3250 3250 3250 3250 3250 3930 3930 3930 3930
H – Height mm 2210 2210 2210 2210 2260 2260 2260 2260 2260 2260 2260
P – Depth mm 1570 1570 1570 1570 1970 1970 1970 1970 1970 1970 1970
TXAETP weight kg 1335 1345 1600 1625 2000 2005 2040 2305 2310 2360 2365
TXAEQP weight kg 1390 1400 1685 1710 2075 2080 2115 2385 2390 2440 2445
SEASONAL ENERGY PERFORMANCE 251 260 270 280 4100 4110 4120 4130 4140 4150 4160
TXAETP MODEL SEASONAL ENERGY PERFORMANCE IN HEATING MODE – Low temperature application 35°C
Pdesignh (EN 14825) kW 41 48 58 65 83 90 98 109 116 124 131
SCOP (EN 14825) 3,74 3,7 3,73 3,73 3,8 3,77 3,75 3,78 3,75 3,74 3,72
ηs % 147 145 146 146 149 148 147 148 147 147 146
Energy class A+ A+ A+ A+ - - - - - - -
TXAEQP MODEL SEASONAL ENERGY PERFORMANCE IN HEATING MODE – Low temperature application 35°C
Pdesignh (EN 14825) kW 40 47 57 64 82 88 96 108 114 121 128
SCOP (EN 14825) 3,73 3,71 3,77 3,76 3,73 3,74 3,71 3,71 3,7 3,69 3,68
ηs % 146 145 148 147 146 147 146 145 145 144 144
Energy class A+ A+ A+ A+ - - - - - - -
TXAETP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
Pdesignh (EN 14825) kW 40 47 56 63 82 88 96 106 113 120 127
SCOP (EN 14825) 3,15 3,11 3,12 3,14 3,22 3,19 3,16 3,23 3,2 3,18 3,18
ηs % 123 121 122 123 126 125 123 126 125 124 124
Energy class A+ A+ A+ A+ - - - - - - -
TXAEQP MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C
Pdesignh (EN 14825) kW 39 46 55 62 81 87 95 105 111 118 125
SCOP (EN 14825) 3,15 3,11 3,15 3,17 3,17 3,15 3,12 3,16 3,14 3,13 3,14
ηs % 123 122 123 124 124 123 122 124 123 122 122
Energy class A+ A+ A+ A+ - - - - - - -
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C.
  • Air: 7°C D.B. – 6°C W.B. – Water: 40/45°C.
  • Evaporator output water: 7℃, nominal flow rate. Recovery output water: 45°C, nominal flow rate.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • Performance according to EN 14511.
  • T.E.R.: Total efficiency ratio
  • In Average climatic conditions
  • Seasonal energy efficiency: heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.