Electa-SAN Plus
TWCTZ 200-300Air-water heat pump for the production of domestic hot water. Rotary hermetic compressor and R134a refrigerant gas.
Key features
Renewable energy water heater
New Electa-SAN Plus models in A+ class
Standard version and with additional solar thermal coil
Heat pump operation with outdoor air temperature from -10°C to +43°C
Contact for integration with photovoltaic system
Description
Construction features
• Carbon steel tank with double layer vitrification and internal treatment according to standards DIN 4753-3.
• Anti-corrosion magnesium anode to ensure the durability of the tank.
• Condenser wrapped externally to the boiler, free from scaling and chiller liquid-water contamination.
• Auxiliary coil for use in combination with solar panels (TWCTZ-S only)
• Thermal insulation in thick expanded polyurethane (PU) (45 and 50 mm).
• Sheet metal coating painted color RAL839.
• Acoustically insulated plastic top cover.
• High efficiency compressor with R134a refrigerant.
• Electronic expansion valve.
• Finned coil heat exchanger with hydrophilic treatment for TCWTZ.
• Safety devices for high and low gas pressure.
• Electrical resistance available in the unit as a back-up with a safety thermostat, which ensures hot water at a constant temperature even in extreme winter conditions.
Electronic control and user interface for unit management:
• Tank temperature display.
• Domestic hot water set-point adjustment.
• Clock display and switch-on and shutdown timer.
• Electrical resistance management, in manual mode or in automatic integration.
• Anti-legionella cycle function, with activation timer.
• Indication of any alarms and malfunctions.
• Contact for integration with a photovoltaic system: the temperature set is raised to the highest possible value, on photovoltaic inverter enabling.
• ON-OFF contact to start the unit from an external switch.
• RS485 interface for serial communication with other devices (Modbus RTU protocol).
Version
• TWCTZ-B: water heater with heat pump.
• TWCTZ-S: water heater with heat pump and additional solar thermal coil.
Technical data
Electa-SAN Plus | Electa-SAN Plus | Electa-SAN Plus | Electa-SAN Plus | |||||
MODEL | TWCTZ-B 200 | TWCTZ-B 300 | TWCTZ-S 200 | TWCTZ-S 300 | ||||
Tank capacity | l | 180 | 270 | 174 | 261 | |||
❶ | Heating capacity | W | 1800 | 1800 | 1800 | 1800 | ||
Absorbed power | W | 460 | 460 | 460 | 460 | |||
Electrical resistance power | W | 1500 | 1500 | 1500 | 1500 | |||
Maximum operating pressure | bar | 7 | 7 | 7 | 7 | |||
❷ | COPDHW | 3,14 | 3,16 | 3,14 | 3,16 | |||
❸ | COPDHW | 3,37 | 3,58 | 3,37 | 3,58 | |||
❶ | heating up time | h:min | 04:46 | 07:02 | 04:46 | 07:02 | ||
❶ | heating up time with active resistance | h:min | 02:36 | 04:01 | 02:36 | 04:01 | ||
❷ | Maximum volume of DHW usable at 40°C | l | 239 | 349 | 239 | 349 | ||
Solar thermal coil surface | m2 | - | - | 1 | 1,5 | |||
Maximum solar coil operating pressure | bar | - | - | 7 | 7 | |||
Nominal air flow | m3/h | 450 | 450 | 450 | 450 | |||
Air flow rate at the maximum available static pressure 60 Pa | m3/h | 350 | 350 | 350 | 350 | |||
Internal sound power | db(A) | 58 | 59 | 58 | 59 | |||
❹ | Sound pressure | db(A) | 43 | 44 | 43 | 44 | ||
Electrical supply | V-ph-Hz | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | |||
Maximum absorbed power | W | 560 | 560 | 560 | 560 | |||
Absorbed power in standby (Pes) | W | 32 | 37 | 32 | 37 | |||
Protection rating | IP | IPX1 | IPX1 | IPX1 | IPX1 | |||
DIMENSIONS AND WEIGHTS | ||||||||
MODEL | TWCTZ-B 200 | TWCTZ-B 300 | TWCTZ-S 200 | TWCTZ-S 300 | ||||
L – Width | mm | 560 | 640 | 560 | 640 | |||
H – Height | mm | 1770 | 1880 | 1770 | 1880 | |||
P – Depth | mm | 590 | 670 | 590 | 670 | |||
Empty weight | kg | 92 | 112 | 113 | 136 | |||
Weight with a full water tank | kg | 272 | 382 | 287 | 397 | |||
ENERGY PERFORMANCE | TWCTZ-B 200 | TWCTZ-B 300 | TWCTZ-S 200 | TWCTZ-S 300 | ||||
WATER HEATING | ||||||||
④ | Load profile | L | XL | L | XL | |||
④ | ηwh | % | 132,3 | 131,5 | 132,3 | 131,5 | ||
④ | Energy class | A+ | A+ | A+ | A+ | |||
④ | Annual energy consumption | kWh/annum | 774 | 1274 | 774 | 1274 | ||
- Data at the following conditions:
- ❶ Air 20°C D.B. – 15°C W.B.; water from 15°C to 55°C.
- ❷ Air 7°C D.B. – 6°C W.B.; water from 10°C to 55°C (EN 16147).
- ❸ Air 14°C D.B. – 12°C W.B.; water from 10°C to 55°C (EN 16147).
- ❹ According to ISO 3744:2010 at 1 m from the unit
- ④ Water heating energy efficiency in average climatic conditions (+7°C). (Regulations (EU) No.812/2013 and No.814/2013)
- Operating range:
- - Inlet air/working ambient temperature: -10 to 43°C
- - Domestic hot water up to 60°C for TWCTZ, 65°C for TWCZ.
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Images
Request information about this product
Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.