Web code: CYP11
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

Compact-Y NF Plus

THAETY 115÷127 NF
Cooling capacity 15,5÷26,6 kW
Heating capacity 16,6÷30,4 kW

Packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant gas.

Features

Tax incentives*

Key features

Hot water up to –15°C outdoor air
Temperature of the produced water up to 60°C
Plug&Play unit with integrated hydraulic module
Included evaporating/condensing control
Integrated MASTER/SLAVE control

Compact-Y NF Plus

Description

Construction features

• Compressor: hermetic, rotary scroll compressor, complete with thermal protection and casing heater for mod. 127.
• Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins with hydrophilic treatment and complete with protection grille.
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed regulation.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate, complete with condensate drain pan and unit base antifreeze heater.
• The unit is also complete with:
- outdoor air temperature probe for compensation of the Set-point;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board.

Version

• T - High efficiency/temperature version.

Models

• THAETY: heat pump unit.

PUMP set-up

• Pump unit complete with: circulator or electric circulation pump, membrane expansion tank, manual air vent valve, safety valve and pressure gauge.

TANK&PUMP set up
• Pump unit complete with: inertial buffer tank, circulator or electric circulation pump, membrane expansion tank, manual air vent valve, automatic air vent valve, safety valve, and pressure gauge.

Factory fitted accessories

• Soft-start device.
• Silenced set up.
• Antifreeze heater on the tank.
• Compressor casing heater (mod. 115-124).
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Low water set-point temperature.

Separately supplied accessories

• 3-way valve for the production of domestic hot water, managed by regulation.
• Additional electrical resistance for heat pump, managed by regulation.
• Outdoor air temperature probe for set-point compensation.
• Rubber anti-vibration mounts.
• Water filter.
• Remote keypad with display.
• Interfaces for serial communication with other devices.
• Serial converter (RS485/USB).
• Rhoss supervisors for unit monitoring and remote management.

Technical data

THAETY NF MODEL 115 117 122 124 127
Heating capacity kW 16,6 17,7 23,4 25,9 30,4
Absorbed power kW 5,72 6,32 8,18 9,08 10,03
C.O.P. 2,9 2,8 2,86 2,85 3,03
Heating capacity kW 18 19 24,8 27,8 32,3
Absorbed power kW 4,33 4,53 5,9 6,59 7,58
C.O.P. 4,16 4,19 4,2 4,22 4,26
Heating capacity kW 11,7 12 15,7 17,9 20,8
C.O.P. 2,77 2,77 2,8 2,77 2,84
Cooling capacity kW 15,5 17,6 22,5 23,9 26,6
Absorbed power kW 5,81 6,62 8,14 9,45 10,11
E.E.R. 2,67 2,66 2,75 2,53 2,63
Sound pressure dB(A) 50 50 52 52 53
Silenced setup sound pressure dB(A) 46 46 49 49 50
Scroll compressors/steps no. 1/1 1/1 1/1 1/1 1/1
Buffer tank water content l 35 35 45 45 45
P0 circulator/P1 electric pump nominal available head kPa 75/155 64/136 66/131 68/130 63/120
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
DIMENSIONS AND WEIGHT 115 117 122 124 127
L – PUMP width mm 1230 1230 1230 1230 1535
L – TANK&PUMP width mm 1522 1522 1522 1522 1822
H – Height mm 1090 1090 1280 1280 1510
P – Depth mm 580 580 600 600 695
Weight kg 215 225 278 288 350
SEASONAL ENERGY PERFORMANCE 115 117 122 124 127
THAETY NF MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 18 18 24 27 32
SCOP (EN 14825) 3,62 3,74 3,72 3,74 3,68
ηs % 142 146 146 146 144
Energy class A+ A+ A+ A+ A+
  • Data at the following conditions:
  • Air: 7°C D.B. – 6°C W.B. – Water: 40/45°C.
  • Air: 7°C D.B. – 6°C W.B. – Water: 30/35°C.
  • Air: -7°C D.B. – Water: 30/35°C.
  • Air: 35°C D.B. – Water: 12/7°C.
  • In open field (Q = 2) at 5 m from the unit.
  • Weight refers to the most complete setup.
  • Performance according to EN 14511. Setup with circulator.
  • Important note:
  • - With circulator (P0/ASP0 setup) the units are not suitable for radiant cooling operation.
  • - Permissible heat exchanger thermal gradient ΔT = 4-8°C.
  • In Average climatic conditions, low temperature application (35°C)
  • Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.