Y-Pack FREECOOLING
TFAEY-TGAEY 4160÷4320Packaged air-cooled water chillers in Freecooling mode (TFAEY) and Freecooling NO-GLYCOL mode (TGAEY) with axial fans. Range with scroll hermetic compressors and R410A refrigerant.
Key features
NO GLYCOL version available
Integrated MASTER/SLAVE control
Plug&Play Range
Description
Construction features
• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• 4 capacity steps with high efficiency at partial loads.
• Water side heat exchanger (evaporator): with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch (TFAEY) or flow switch (TGAEY).
• Heat exchanger (water-water) in Freecooling NO-GLYCOL: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger (condenser): featuring finned coil with copper pipes and aluminium fins.
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed regulation.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- fan and compressor circuit breaker switches;
- Master/Slave control up to 4 units in parallel;
- clock board;
- water side 3-way modulating valve.
Versions
• T - High efficiency version (TFAETY-TGAETY).
• S - Silenced version complete with compressor technical compartment soundproofing and reduced speed fans (TFAESY - TGAESY).
Models
• TFAETY: high efficiency unit in Freecooling mode.
• TFAESY: silenced unit in Freecooling mode.
• TGAETY: high efficiency unit in NO-GLYCOL Freecooling mode.
• TGAESY: silenced unit in NO-GLYCOL Freecooling mode.
Factory fitted accessories
• PUMP with single or double electric pump, including an automatic actuation pump in standby complete with safety valve. The electric pumps are available in the low or high head versions.
• TANK&PUMP with integrated 700 litres buffer tank and single or double electric pump, complete with expansion tank, air vent valves, safety valve, and water side pressure gauge.
• Electronic expansion valve.
• Power factor correction capacitors (cosφ > 0.94).
• Soft starter.
• Cooling circuit high and low pressure gauges.
• Metal filters or coil protection nets.
• Copper/copper or copper/pre-painted aluminium coils.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electric pumps if applicable.
• Interfaces for serial communication with other devices.
• Anti-vibration mounts.
Separately supplied accessories
• Remote keypad with display.
• Rhoss supervisors for unit monitoring and remote management.
Technical data
TFAETY-TFAESY MODEL | 4160 | 4180 | 4200 | 4230 | 4260 | 4290 | 4320 | ||||
FREE-COOLING OFF | |||||||||||
❶ | Nominal cooling capacity | kW | 178 | 202 | 224 | 251 | 286 | 326 | 361 | ||
❶ | Nominal cooling capacity | kW | 170 | 197 | 215 | 240 | 274 | 312 | 344 | ||
❶ | E.E.R. | 3,31 | 3,41 | 3,27 | 3,2 | 3,34 | 3,2 | 3,09 | |||
❶ | E.E.R. | 3,21 | 3,32 | 3,11 | 3,11 | 3,22 | 3,09 | 2,92 | |||
❶ | Absorbed power | kW | 53,8 | 59,3 | 68,4 | 78,5 | 85,6 | 102 | 117 | ||
❶ | Absorbed power | kW | 53 | 59,3 | 69,2 | 77,2 | 85,2 | 100,9 | 117,9 | ||
FREE-COOLING ON 100% | |||||||||||
❷ | Nominal cooling capacity | kW | 178 | 202 | 224 | 251 | 286 | 326 | 361 | ||
❷ | Nominal cooling capacity | kW | 170 | 197 | 215 | 240 | 274 | 312 | 344 | ||
❷ | E.E.R. | 21,3 | 24,4 | 26,9 | 20,5 | 22,8 | 19,5 | 21,5 | |||
❷ | E.E.R. | 33 | 37,8 | 41,4 | 31,7 | 35,2 | 30 | 32,9 | |||
❷ | Absorbed power | kW | 8 | 8 | 8 | 12 | 12 | 16 | 16 | ||
❷ | Absorbed power | kW | 5 | 5 | 5 | 7,5 | 7,5 | 10 | 10 | ||
❷ | Total Free-cooling Temperature | °C | 0,3 | 1 | 0,4 | 0,7 | 0,9 | 0,4 | –0,8 | ||
❷ | Total Free-cooling Temperature | °C | –1,3 | –0,8 | –1,5 | –1,3 | –1,1 | –1,6 | –3,0 | ||
TFAETY-TFAESY MODEL | 4160 | 4180 | 4200 | 4230 | 4260 | 4290 | 4320 | ||||
❸ | Sound pressure | dB(A) | 60 | 63 | 63 | 65 | 65 | 66 | 66 | ||
❸ | Sound pressure | dB(A) | 55 | 56 | 56 | 58 | 59 | 60 | 60 | ||
❹ | Sound power | dB(A) | 89 | 91 | 91 | 93 | 93 | 94 | 94 | ||
❹ | Sound power | dB(A) | 85 | 86 | 86 | 88 | 89 | 90 | 90 | ||
Scroll compressors/steps | n. | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | |||
Circuits | n. | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |||
Electrical supply | V-ph-Hz | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | |||
DIMENSIONS AND WEIGHTS | 4160 | 4180 | 4200 | 4230 | 4260 | 4290 | 4320 | ||||
L – Width | mm | 4.800 | 4.800 | 4.800 | 4.800 | 5.300 | 5.300 | 5.300 | |||
H – Height | mm | 2.030 | 2.030 | 2.030 | 2.030 | 2.030 | 2.030 | 2.030 | |||
P – Depth | mm | 2.090 | 2.090 | 2.090 | 2.090 | 2.090 | 2.090 | 2.090 | |||
❺ | TFAETY-TFAESY Weight | kg | 2.370 | 2.820 | 2.920 | 3.020 | 3.230 | 3.380 | 3.430 | ||
❺ | TGAETY-TGAESY Weight | kg | 2.470 | 2.970 | 3.070 | 3.170 | 3.280 | 3.430 | 3.480 | ||
SEASONAL ENERGY PERFORMANCE | 4160 | 4180 | 4200 | 4230 | 4260 | 4290 | 4320 | ||||
TFAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||||
⑤ | PdesignR | kW | 158,2 | 179,4 | 198,9 | 222,8 | 254 | 289,5 | 320,5 | ||
⑤ | SEPR | 5,29 | 5,39 | 5,32 | 5,22 | 5,33 | 5,24 | 5,19 | |||
TFAESY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||||
⑤ | PdesignR | kW | 151,2 | 175,1 | 191 | 213,1 | 243,5 | 277,1 | 305,5 | ||
⑤ | SEPR | 5,28 | 5,31 | 5,24 | 5,19 | 5,27 | 5,21 | 5,14 | |||
TGAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||||
⑤ | PdesignR | kW | 155,3 | 178,4 | 197,4 | 220,6 | 250,9 | 286,9 | 317,1 | ||
⑤ | SEPR | 5,21 | 5,24 | 5,24 | 5,14 | 5,21 | 5,14 | 5,02 | |||
TGAESY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||||
⑤ | PdesignR | kW | 148,5 | 171,6 | 188,9 | 211,1 | 240,7 | 274,2 | 300,9 | ||
⑤ | SEPR | 5,1 | 5,16 | 5,18 | 5,16 | 5,15 | 5,02 | 5,02 | |||
- Data at the following conditions:
- ❶ Air: 30°C – Water: 15/10°C – Ethylene glycol 30%.
- ❷ Water: 15/10°C – Ethylene glycol 30%.
- ❸ In open field (Q = 2) at 10 m from the unit.
- ❹ Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
- ❺ Weight referred to the accessorised unit without load.
- ■ TFAESY silenced version.
- ⑤ Application for high temperature (7°C) process chiller (EU Regulation 2016/2281)
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Images
Request information about this product
Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.