Web code: FFE03
CHILLERS HEAT PUMPS WATER-cooled CONDENSERLESS UNITS

FullFLOW VFD (1+i)

TCHITL 1390÷21700
Cooling capacity 389,5÷1701,1 kW

Water-cooled water chillers. Range with semi-hermetic screw compressors with variable Vi, inverter regulation and R513A refrigerant gas.

Features

Key features


Non-flammable reduced GWP gas

High efficiency levels

Continuous power regulation

Various soundproofing options

Touch interface (optional)

Free-Cooling management

Integrated MASTER/SLAVE control


FullFLOW VFD (1+i)

Description

Construction features

• Compressor: high energy efficiency semi-hermetic screw driven by fixed speed motor with linear capacity control and/or variable Vi regulated by inverter (25%-100% single-compressor sizes, 12.5-100% bi-compressor sizes), limited start, complete with integral protection, casing heater, oil level sensor and shut-off valves on delivery and intake piping.
• Water side heat exchanger (evaporator): low refrigerant charge spray flooded type shell and tube exchanger, complete with closed cell polyurethane foam rubber insulation, water flow differential pressure switch and Victaulic fittings.
• Water side heat exchanger (condenser): tube and shell complete with safety valve, service valve on the high-pressure refrigerant gas circuit, and a water flow differential pressure switch and Victaulic fittings.
• Control: microprocessor electronic control.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- clock board;
- electronic expansion valve;
- display of cooling circuit high/low pressure;
- Master/Slave control up to 4 units in parallel;
- 0-10V analogue signal for condensing control from external device;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version

Models

• TCHITL: unit designed for cooling only.

Factory fitted accessories

• Free-Cooling management
• Dry-Cooler management
• 100% heat recovery unit.
• Set up for heat pump operation.
• Power factor correction capacitors (cosφ > 0.94).
• Circuit breaker switches.
• Forced limit of power consumption.
• Soft starter.
• Electro-mechanical flow switch.
• EMC anti-disturbance filters.
• Energy parameter measuring device.
• Compressor soundproof enclosures.
• Full acoustic casing.
• Refrigerant leak detector.
• Double safety valves.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater.
• Control of min/max power supply voltage.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7” display.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Outdoor air temperature probe for set-point compensation
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCHITL MODEL 1390 1490 1600 2720 2810 2900 21000 21110 21260 21360 21520 (*) 21700 (*)
Nominal cooling capacity kW 389,5 486,5 610,4 727,4 816,3 920,3 1001,3 1117,2 1260,2 1361,1 1524,2 1701,1
E.E.R. 5,18 5,16 5,11 5,5 5,41 5,5 5,45 5,32 5,36 5,4 5,57 5,55
Absorbed power kW 75,2 94,3 119,5 132,3 150,9 167,3 183,7 210 235,1 252,1 273,6 306,5
Sound power dB(A) 97 99 101 98 98 100 100 102 103 103 102 103
Sound power with enclosure accessory dB(A) 93 95 97 94 94 96 96 98 99 99 98 99
Screw compressors n. 1 1 1 2 2 2 2 2 2 2 2 2
Circuits n. 1 1 1 2 2 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 1390 1490 1600 2720 2810 2900 21000 21110 21260 21360 21520 21700
L – Width mm 3859 3859 3859 3990 3990 3990 4329 4407 4407 4407 4501 4586
H – Height mm 1830 1830 1830 2040 2040 2040 2040 2040 2080 2080 2090 2090
P – Depth mm 1531 1531 1591 1676 1676 1676 1676 1814 1844 1844 1979 2024
TCHITL weight kg 2460 2530 2605 4700 4830 4915 5385 5600 6325 6455 7765 8115
SEASONAL ENERGY PERFORMANCE 1390 1490 1600 2720 2810 2900 21000 21110 21260 21360 21520 (*) 21700 (*)
TCHITL MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 389,5 486,5 610,4 727,4 816,3 920,3 1001,3 1117,2 1260,2 1361,1 1524,2 1701,1
SEER  (EN 14825) 8,52 8,22 8,16 8,18 8,43 8,34 8,1 8,04 8 8,03 8,1 7,96
ηs,c % 338 326 323 324 334 331 321 319 317 318 321 316
  • Data at the following conditions:
  • Chilled water: 7/12°C. – Condenser inlet water: 30/35°C.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Empty weight.
  • Performance according to EN 14511.
  • (*) Unit not Eurovent certified.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.