Web code: FFE04
CHILLERS HEAT PUMPS WATER-cooled CONDENSERLESS UNITS

FullFLOW ECO VFD (1+i)

TCHITE 1280÷21220
Cooling capacity 285,6÷1217,2 kW

Water-cooled water chillers. Range with semi-hermetic screw compressors with variable Vi, inverter regulation and R1234ze refrigerant gas.

Features

Key features

HFO R1234ze ecological gas
High efficiency levels
Continuous power regulation
Various soundproofing options
Touch interface (optional)
Free-Cooling management
Integrated MASTER/SLAVE control

FullFLOW ECO VFD (1+i)

Description

Construction features

• Compressor: high energy efficiency semi-hermetic screw driven by fixed speed motor with linear capacity control and/or variable Vi regulated by inverter (25-100% single-compressor sizes, 12.5-100% bi-compressor sizes), limited start, complete with integral protection, casing heater, oil level sensor and shut-off valves on delivery and intake piping.
• Water side heat exchanger (evaporator): low refrigerant charge spray flooded type shell and tube exchanger, complete with closed cell polyurethane foam rubber insulation, water flow differential pressure switch and Victaulic fittings.
• Water side heat exchanger (condenser): tube and shell complete with safety valve, service valve on the high-pressure refrigerant gas circuit, and a water flow differential pressure switch and Victaulic fittings.
• Control: microprocessor electronic control.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- clock board;
- electronic expansion valve;
- display of cooling circuit high/low pressure;
- Master/Slave control up to 4 units in parallel;
- 0-10V analogue signal for condensing control from external device;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version

Models

• TCHITE: unit designed for cooling only.

Factory fitted accessories

• Free-Cooling management
• Dry-Cooler management
• 100% heat recovery unit.
• Set up for heat pump operation.
• Power factor correction capacitors (cosφ > 0.94).
• Circuit breaker switches.
• Forced limit of power consumption.
• Soft starter.
• Electro-mechanical flow switch.
• EMC anti-disturbance filters.
• Energy parameter measuring device.
• Compressor soundproof enclosures.
• Full acoustic casing.
• Refrigerant leak detector.
• Double safety valves.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater.
• Control of min/max power supply voltage.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7” display.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Outdoor air temperature probe for set-point compensation.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCHITE MODEL 1280 1340 1430 2520 2580 2650 2710 2800 2890 2970 21090 21220
Nominal cooling capacity kW 285,6 346,6 434,5 524,4 584,4 648,4 719,4 800,4 897,3 974,3 1091,2 1217,2
E.E.R. 5,2 5,19 5,05 5,47 5,44 5,43 5,5 5,33 5,32 5,39 5,54 5,54
Absorbed power kW 54,9 66,8 86 95,9 107,4 119,4 130,8 150,2 168,7 180,8 197 219,7
Sound power dB(A) 97 99 101 98 98 100 100 102 103 103 102 103
Sound power with enclosure accessory dB(A) 93 95 97 94 94 96 96 98 99 99 98 99
Screw compressors n. 1 1 1 2 2 2 2 2 2 2 2 2
Circuits n. 1 1 1 2 2 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 1280 1340 1430 2520 2580 2650 2710 2800 2890 2970 21090 21220
L – Width mm 3859 3859 3859 4008 4008 3990 4329 4407 4407 4407 4501 4586
H – Height mm 1830 1830 1830 1910 1910 2040 2040 2040 2040 2040 2080 2080
P – Depth mm 1531 1531 1591 1676 1676 1676 1676 1814 1844 1844 1964 2009
TCHITE weight kg 2335 2440 2535 4095 4190 4735 5205 5355 5620 5765 6790 7135
SEASONAL ENERGY PERFORMANCE 1280 1340 1430 2520 2580 2650 2710 2800 2890 2970 21090 21220
TCHITE MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 285,6 346,6 434,5 524,4 584,4 648,4 719,4 800,4 897,3 974,3 1091,2 1217,2
SEER  (EN 14825) 8,41 8,18 8,09 8,11 8,34 8,23 7,84 8,02 7,88 7,94 7,97 7,96
ηs,c % 333 324 321 321 331 326 311 318 312 315 316 315
  • Data at the following conditions:
  • Chilled water: 7/12°C. – Condenser inlet water: 30/35°C.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Empty weight.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product









    Find an agent or a reseller.