Y-Flow
TCHEY-THHEY 115÷240Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit with water-cooling system. Range with scroll hermetic compressors and R410A refrigerant gas.
Key features
Applications with well water, water mains or geothermal probes
Plug&Play Unit with upward hydraulic connections
Description
Construction features
• Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater.
• Primary side (user) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Disposal unit side (well/mains/geothermal probes) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch (for THHEY).
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating, internally covered with soundproof panelling.
Models
• TCHEY: unit designed for cooling only.
• THHEY: heat pump unit.
STANDARD set up
Without electric circulation pump and hydraulic accessories.
Factory fitted accessories
• PUMP:
- Primary side (user): pump unit complete with electric circulation pump with standard or oversized head, membrane expansion tank, safety valve, water fill/drain valve, manual air vent valve and pressure gauge.
- Disposal side (geothermal probes/dry cooler): pump unit complete with phase cutting electric pump, water fill/drain valve and manual air vent valve.
• Silenced set up.
• Pressure switch valve with water flow lock solenoid.
• Pressure switch valve with water flow lock solenoid and bypass solenoid valve.
• Set up for heat pump operation (for TCHEY only).
• Soft-start device.
• Low temperature water production.
• Digital input for double set-point.
• 4-20mA analogue signal for shifting set-point.
• Refrigerant leak detector.
• Forced limit of power consumption.
Separately supplied accessories
• 3-way valve for the production of domestic hot water.
• Additional electrical resistance for heat pump, managed by regulation.
• Outdoor air temperature probe for set-point compensation.
• Free-cooling kit.
• Water filter.
• Rubber anti-vibration mounts.
• Remote keypad with display.
• Interfaces for serial communication with other devices.
• Serial converter (RS485/USB).
• Rhoss supervisors for unit monitoring and remote management.
Technical data
TCHEY MODEL | 115 | 118 | 122 | 125 | 230 | 240 | ||||
❶ | Cooling capacity | kW | 15,5 | 18,4 | 22,7 | 26,3 | 30,5 | 41,7 | ||
❶ | Absorbed power | kW | 3,27 | 3,49 | 4,5 | 5,01 | 6,64 | 8,07 | ||
❶ | E.E.R. | 4,74 | 5,27 | 5,04 | 5,25 | 4,59 | 5,17 | |||
THHEY MODEL | 115 | 118 | 122 | 125 | 230 | 240 | ||||
❷ | Heating capacity | kW | 17,4 | 20,2 | 25,1 | 28,9 | 35,9 | 45,1 | ||
❷ | Absorbed power | kW | 3,95 | 4,41 | 5,59 | 6,3 | 8,05 | 10,11 | ||
❷ | C.O.P. | 4,4 | 4,58 | 4,49 | 4,59 | 4,46 | 4,46 | |||
❸ | Heating capacity | kW | 18,6 | 21,5 | 26,6 | 30,7 | 38,5 | 47,9 | ||
❸ | Absorbed power | kW | 3,29 | 3,55 | 4,45 | 5,04 | 6,63 | 8,09 | ||
❸ | C.O.P. | 5,66 | 6,05 | 5,97 | 6,09 | 5,81 | 5,92 | |||
❹ | Heating capacity (geothermal) | kW | 13,4 | 15,3 | 18,6 | 21,7 | 27,7 | 33,8 | ||
❹ | C.O.P. (geothermal) | 4,12 | 4,21 | 4,37 | 4,49 | 4,23 | 4,3 | |||
❶ | Cooling capacity | kW | 13,9 | 16,3 | 20 | 23,1 | 27,3 | 35,9 | ||
❶ | E.E.R. | 3,81 | 4,13 | 4,15 | 4,19 | 3,79 | 4,09 | |||
TCHEY – THHEY MODEL | 115 | 118 | 122 | 125 | 230 | 240 | ||||
❺ | Sound pressure | dB(A) | 42 | 42 | 46 | 47 | 48 | 52 | ||
Scroll compressors/steps | n. | 1/1 | 1/1 | 1/1 | 1/1 | 2/2 | 2/2 | |||
Circuits | no. | 1 | 1 | 1 | 1 | 1 | 1 | |||
❶ | Std system side electric pump available head | kPa | 88 | 81 | 73 | 113 | 105 | 115 | ||
Electrical supply | V-ph-Hz | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | |||
DIMENSIONS AND WEIGHTS | 115 | 118 | 122 | 125 | 230 | 240 | ||||
L – Width | mm | 700 | 700 | 700 | 700 | 700 | 700 | |||
H – STANDARD height – PUMP | mm | 1140 | 1140 | 1140 | 1140 | 1140 | 1140 | |||
P – Depth | mm | 560 | 560 | 780 | 780 | 780 | 780 | |||
❻ | Weight | kg | 193 | 193 | 230 | 254 | 278 | 298 | ||
SEASONAL ENERGY PERFORMANCE | 115 | 118 | 122 | 125 | 230 | 240 | ||||
TCHEY MODEL SEASONAL PERFORMANCE IN COOLING MODE | ||||||||||
① | Pdesignc (EN 14825) | kW | 15,5 | 18,4 | 22,7 | 26,3 | 30,5 | 41,7 | ||
① | SEER (EN 14825) | 5,33 | 5,57 | 5,55 | 5,7 | 6,06 | 5,81 | |||
② | ηs,c | % | 210 | 220 | 219 | 225 | 239 | 229 | ||
THHEY MODEL SEASONAL PERFORMANCE IN HEATING MODE | ||||||||||
③ | Pdesignh (EN 14825) | kW | 23 | 27 | 33 | 38 | 48 | 59 | ||
③ | SCOP (EN 14825) | 6,1 | 6,43 | 6,44 | 6,54 | 6,67 | 6,8 | |||
④ | ηs | % | 236 | 249 | 249 | 254 | 259 | 264 | ||
④ | Energy class | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |||
- Data at the following conditions:
- ❶ Chilled water: 12/7°C – Condenser water: 30/35°C.
- ❷ Hot water: 40/45°C – Evaporator water: 10/7°C.
- ❸ Hot water: 30/35°C – Evaporator water: 10/7°C.
- ❹ Hot water: 30/35°C – Evaporator water: 0/–3°C, 30% glycol.
- ❺ In open field (Q = 2) at 1 m from the unit, with silenced setup.
- ❻ Weight refers to the most complete setup.
- Performance according to EN 14511.
- ① Low temperature application (7°C)
- ② Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
- ③ In Average climatic conditions, low temperature application (35°C)
- ④ Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Images
Request information about this product
Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.