New
Web code (TCEETU): EFC05 Web code (TCEETY): EFC01
CHILLERS HEAT PUMPS WATER-cooled CONDENSERLESS UNITS

EasyFLOW ECO E EasyFLOW E

TCEET 245÷2195
Cooling capacity 38,6÷170,5 kW

Cooling only condenserless units to couple with a remote condenser. Series with scroll hermetic compressors and R454B or R410A refrigerant gas.

Features

Key features


Condenserless units

Efficient and eco-friendly range in R454B

Extended operating limits

Touch interface (optional)

Integrated MASTER/SLAVE control


EasyFLOW ECO E EasyFLOW E

Description

Construction features

• Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater.
• Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- compressor circuit breaker switches;
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- 0-10V analogue signal for condensing control from external device.

Versions

• T - High efficiency version

Models

• TCEETU: unit designed for cooling only with R454B gas.
• TCEETY: unit designed for cooling only with R410A gas.

Factory fitted accessories

• VPF control.
• Primary side (user) PUMP: with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high pressure head versions. ➔
• Desuperheater.
• Primary side (user) inverter pump management.
• Power factor correction capacitors (cosφ > 0.94).
• Soft-starter.
• Energy parameter measuring device.
• Cooling circuit intake valves.
• Refrigerant leak detector.
• Forced limit of power consumption.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Technical compartment soundproofing.
• Compressor soundproof enclosures
• Control of min/max power supply voltage and backup battery.
• Low temperature water production.
• Digital input for double set-point.
• 4-20mA analogue signal for shifting set-point.
• Evaporator antifreeze heaters, electrical panel, electric pumps and heat exchangers for heat recovery if applicable.
• Interfaces for serial communication with other devices.
• Colour touch user keypad (fitted on the machine or remotely) with 7'' display.
• Set-up for outdoor installation.
• Rubber anti-vibration mounts.

Separately supplied accessories

• Outdoor air temperature probe for set-point compensation.
• Water filter.
• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCEETU MODEL 245 255 260 270 280 290 2105 2120 2135 2155 2175 2195
Cooling capacity kW 38,6 45,8 52,6 59,9 66,1 78,6 90,7 102,6 114,9 127,7 146,6 166,3
Absorbed power kW 12,8 15 16 18,1 19,7 23,6 27,2 32,1 35,8 40,6 46,8 53
E.E.R. 3,02 3,05 3,29 3,31 3,36 3,33 3,33 3,2 3,21 3,15 3,13 3,14
TCEETU MODEL 245 255 260 270 280 290 2105 2120 2135 2155 2175 2195
Sound pressure dB(A) 38 40 39 41 41 42 42 44 44 46 47 48
Sound power dB(A) 69 71 70 72 72 74 74 76 76 78 79 80
Sound power with soundproofing set-up dB(A) 66,5 68,5 67,5 69,5 69,5 71,5 71,5 73,5 73,5 75,5 76,5 77,5
Scroll compressor/steps no. 2/2 2/2 2/2 2/3 2/3 2/2 2/3 2/3 2/3 2/2 2/3 2/2
Circuits no. 1 1 1 1 1 1 1 1 1 1 1 1
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
DIMENSIONS AND WEIGHTS 245 255 260 270 280 290 2105 2120 2135 2155 2175 2195
L – Width mm 1190 1190 1190 1190 1190 1500 1500 1500 1500 1500 1500 1500
L – Width mm 2060 2060 2060 2060 2060 2460 2460 2460 2460 2460 2460 2460
H – Height mm 1450 1450 1450 1450 1450 1860 1860 1860 1860 1860 1860 1860
P – Depth mm 720 720 720 720 720 870 870 870 870 870 870 870
TCEETU weight kg 390 400 440 445 450 625 630 720 730 810 820 825
TCEETY MODEL 245 255 260 270 280 290 2105 2120 2135 2155 2175 2195
Cooling capacity kW 40,2 47,8 53,9 61,9 68,9 80,6 93,1 105,2 117,9 131,4 150,4 170,5
Absorbed power kW 13,6 15,9 16,8 19 20,7 24,6 28,6 33,5 37,5 42,4 49 55,6
E.E.R. 2,96 3,01 3,21 3,26 3,33 3,28 3,26 3,14 3,14 3,1 3,07 3,07
TCEETY MODEL 245 255 260 270 280 290 2105 2120 2135 2155 2175 2195
Sound pressure dB(A) 38 40 39 41 41 42 42 44 44 46 47 48
Sound power dB(A) 69 71 70 72 72 74 74 76 76 78 79 80
Sound power with soundproofing set-up dB(A) 66,5 68,5 67,5 69,5 69,5 71,5 71,5 73,5 73,5 75,5 76,5 77,5
Scroll compressor/steps no. 2/2 2/2 2/2 2/3 2/3 2/2 2/3 2/3 2/3 2/2 2/3 2/2
Circuits no. 1 1 1 1 1 1 1 1 1 1 1 1
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
DIMENSIONS AND WEIGHTS 245 255 260 270 280 290 2105 2120 2135 2155 2175 2195
L – Width mm 1190 1190 1190 1190 1190 1500 1500 1500 1500 1500 1500 1500
L – Width mm 2060 2060 2060 2060 2060 2460 2460 2460 2460 2460 2460 2460
H – Height mm 1450 1450 1450 1450 1450 1860 1860 1860 1860 1860 1860 1860
P – Depth mm 720 720 720 720 720 870 870 870 870 870 870 870
TCEETY weight kg 390 400 440 445 450 625 630 720 730 810 820 825
  • Data at the following conditions:
  • Chilled water: 12/7°C – Condensing temperature: 50°C (dew point)
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Width referred to a unit with standard set up.
  • Width referring to the PUMP setup, up to a maximum of 2 pumps.
  • Weight refers to the unit empty with soundproofing.

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.