Compact-ID
TCCITY-THCITY 117÷128Packaged air-cooled water chillers and reversible heat pumps with Plug-Fans with EC motor. Range with scroll hermetic compressors, DC Inverter and R410A refrigerant gas.
Key features
PLUG-FANS with low consumption EC motor
Vertically or horizontally ducted delivery.
Hot water up to –15°C outdoor air
Temperature of the produced water up to 60°C
Integrated MASTER/SLAVE control
Inertial buffer tank
Description
• Compressor: scroll type, rotary, hermetic with Inverter actuation, complete with thermal protection and casing heater.
• Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
• Air side heat exchanger: featuring a finned coil with copper pipes and aluminium fins for TCCITY and with hydrophilic treatment for THCITY, complete with protection grilles.
• Fan: Plenum electric fan with directly coupled, low consumption EC motor fitted with internal thermal protection and accident protection grilles. Removable fan unit section for on-site positioning.
• Vertical condensing air delivery, horizontal outlet easily transformed on-site.
• Proportional electronic device for the continuous regulation of the fan rotation speed up to a temperature of outdoor air of -10°C when running as a chiller.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: made of galvanised and painted steel plate, complete with condensate drain pan and unit base antifreeze heater for THCITY.
• The unit is also complete with:
- outdoor air temperature probe for set-point compensation;
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board.
Version
T - High efficiency.
Models
TCCITY: unit designed for cooling only.
THCITY: heat pump unit.
PUMP set-up
• Pump unit complete with: EC circulator with 3 speed selector or continuous speed regulation or electric pump, membrane expansion tank, manual air vent valve, safety valve and pressure gauge.
TANK&PUMP set up
• Pump unit complete with: inertial buffer tank, circulator or electric circulation pump, membrane expansion tank, manual air vent valve, safety valve, and pressure gauge.
Factory fitted accessories
• Forced Download. Compressor partialisation or switch-off to limit power and current consumption (digital input).
• Antifreeze heater on the tank.
• Circulator/electric pump antifreeze heater.
• Pre-painted copper/coils or copper/copper coils.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Low water set-point temperature.
Accessories supplied loose
• 3-way valve for the production of domestic hot water, managed by regulation.
• Additional electrical resistance for heat pump, managed by regulation.
• Remotable outdoor air temperature probe for compensation of the set-point.
• Delivery anti-vibration fitting.
• Suction duct fitting.
• Water filter.
• Rubber anti-vibration mounts.
• Remote keypad with display.
• Interfaces for serial communication with other devices.
• RS485/USB serial converter.
• Rhoss supervisors for unit monitoring and remote management.
Technical data
TCCITY MODEL | 117 | 124 | 128 | ||||
❶ | Cooling capacity | kW | 16,4 | 24,3 | 27,5 | ||
❶ | NOM absorbed power | kW | 5,24 | 8,15 | 9,01 | ||
❶ | E.E.R. | 3,13 | 2,98 | 3,05 | |||
THCITY MODEL | 117 | 124 | 128 | ||||
❷ | Heating capacity | kW | 17,7 | 24,3 | 28,5 | ||
❷ | NOM absorbed power | kW | 5,33 | 7,48 | 8,88 | ||
❷ | C.O.P. | 3,32 | 3,25 | 3,21 | |||
❸ | Heating capacity | kW | 18,8 | 25 | 29,1 | ||
❸ | NOM absorbed power | kW | 4,59 | 6,1 | 7,28 | ||
❸ | C.O.P. | 4,1 | 4,1 | 4 | |||
❹ | Heating capacity | kW | 12,3 | 18,1 | 22,9 | ||
❹ | NOM absorbed power | kW | 4,14 | 6,65 | 7,46 | ||
❹ | C.O.P. | 2,97 | 2,72 | 3,07 | |||
❶ | MIN/NOM/MAX cooling capacity | 16,2 | 23,8 | 27 | |||
❶ | E.E.R. | 2,98 | 2,84 | 2,91 | |||
TCCITY – THCITY MODEL | 117 | 124 | 128 | ||||
❺ | Fan delivery sound pressure | dB(A) | 53 | 53 | 56 | ||
❺ | Machine body sound pressure | dB(A) | 42 | 42 | 45 | ||
Fan nominal air flow | m3/h | 7600 | 7600 | 8640 | |||
Fan available static pressure | Pa | 80 | 80 | 80 | |||
❶ | P0 circulator available head | kPa | 89 | 89 | 76 | ||
Buffer tank water content | l | 110 | 110 | 110 | |||
Electrical supply | V-ph-Hz | 400-3+N-50 | 400-3+N-50 | 400-3+N-50 | |||
DIMENSIONS AND WEIGHT | 117 | 124 | 128 | ||||
L – PUMP width | mm | 1522 | 1522 | 1522 | |||
L – TANK&PUMP width | mm | 1625 | 1625 | 1625 | |||
H – PUMP height | mm | 1280 | 1280 | 1280 | |||
H – TANK&PUMP height | mm | 1590 | 1590 | 1590 | |||
P – PUMP Depth | mm | 815 | 815 | 815 | |||
P – TANK&PUMP Depth | mm | 815 | 815 | 815 | |||
❻ | PUMP Weight | kg | 265 | 285 | 295 | ||
❻ | TANK&PUMP Weight | kg | 365 | 385 | 395 | ||
SEASONAL ENERGY PERFORMANCE | 117 | 124 | 128 | ||||
TCCITY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||
① | Pdesignc (EN 14825) | kW | 16,4 | 24,3 | 27,5 | ||
① | SEER (EN 14825) | 4,54 | 4,52 | 4,59 | |||
② | ηs,c | % | 179 | 178 | 181 | ||
THCITY MODEL SEASONAL PERFORMANCE IN HEATING MODE – Low temperature application 35°C | |||||||
③ | Pdesignh (EN 14825) | kW | 19 | 28 | 35 | ||
③ | SCOP (EN 14825) | 4,14 | 3,53 | 3,69 | |||
④ | ηs | % | 162 | 138 | 145 | ||
④ | Energy class | A++ | A+ | A+ | |||
THCITY MODEL SEASONAL PERFORMANCE IN HEATING MODE – Medium temperature application 55°C | |||||||
③ | Pdesignh (EN 14825) | kW | 16 | - | - | ||
③ | SCOP (EN 14825) | 3,08 | - | - | |||
④ | ηs | % | 120 | - | - | ||
④ | Energy class | A+ | - | - | |||
- Data at the following conditions:
- ❶ Air: 35°C D.B. – Water: 12/7°C.
- ❷ Air: 7°C D.B. – 6°C W.B. – Water: 40/45°C.
- ❸ Air: 7°C D.B. – 6°C W.B. – Water: 30/35°C.
- ❹ Air: -7°C D.B. – Water: 30/35°C.
- ❺ In open field (Q = 2) at 5 m from the unit and ducted fan.
- ❻ Weight refers to the most complete setup.
- Performance according to EN 14511. P0/PI0 setup.
- ① Low temperature application (7°C)
- ② Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
- ③ In Average climatic conditions.
- ④ Seasonal energy efficiency: ambient heating in Average climate (EU Regulations No.811/2013 and No.813/2013)
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Images