Web code: EAI01
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

EasyPACK-I

TCAIY-THAIY 270÷2130
Cooling capacity 67,1÷130,4 kW
Heating capacity 71,2÷134,6 kW

Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors, DC Inverter and R410A refrigerant.

Features

Tax incentives*

Key features


Chillers and heat pumps with inverter compressors

Precise and efficient power modulation

Plug&Play unit with integrated hydronic module and heat recovery

Integrated MASTER/SLAVE control


EasyPACK-I

Description

Construction features

• Compressor: scroll type, rotary, hermetic and with Inverter actuation (1+i) complete with thermal protection and casing heater.
• Continuous regulation with high efficiency at partial loads.
• Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring micro-channels (TCAIY) or finned coil with copper pipes and aluminium fins (THAIY).
• Fan: external rotor axial type electric fans with internal thermal protection, accident protection grilles. The electric fans, based on the sizes, are EC fans or fitted with a proportional electronic device for continuous regulation of the rotation speed of the fans.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- compressor and fan circuit breaker switches;
- electronic expansion valve;
- display of cooling circuit high and low pressure;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version with oversized condensing section (TCAITY-THAITY).
• Q - Super-silenced version complete with compressor technical compartment soundproofing, reduced speed fans and oversized condensing section (TCAIQY-THAIQY).

Models

• TCAITY: high efficiency unit designed for cooling only.
• TCAIQY: super silenced unit designed for cooling only.
• THAITY: high efficiency heat pump unit.
• THAIQY: super silenced heat pump unit.

Factory fitted accessories

• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 230 - 440 litre integrated buffer tank (depending on the sizes) and single or double electric pump, complete with expansion tank, air vent valves, safety valve and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit
• Condensing control with fans with EC motor (standard in sizes 270-2100).
• Condensing control with over-pressure fans (T version only)
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Optimised energy efficiency.
• Soft starter.
• Technical compressor compartment soundproofing.
• Compressor soundproof enclosures.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Metal filters or coil protection nets.
• Microchannel coils with E-coating treatment, copper/copper, copper/aluminium or pre-painted copper/aluminium depending on the versions.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable.
• Interfaces for serial communication with other devices.
• Rubber anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCAITY-TCAIQY MODEL 270 280 290 2100 2115 1 inverter + 1
Nominal cooling capacity kW 69,8 82,6 90,3 97,9 117 130,4
Nominal cooling capacity kW 67,8 80,8 87,7 93,4 111,4 125,5
E.E.R. 3,16 3,17 3,15 3,02 3,1 3,14
E.E.R. 3,01 3,06 3 2,84 2,9 3,01
Absorbed power kW 22,09 26,06 28,67 32,42 37,74 41,53
Absorbed power kW 22,52 26,41 29,23 32,89 38,41 41,69
THAITY-THAIQY MODEL 270 280 290 2100 2115 2130
Nominal heating capacity kW 73,4 85,4 92,5 100,6 121,5 134,6
Nominal heating capacity kW 71,2 83,4 90,4 98,7 117,4 130,6
C.O.P. 3,37 3,34 3,36 3,34 3,37 3,32
C.O.P. 3,31 3,33 3,32 3,3 3,34 3,36
Nominal cooling capacity kW 67,1 79,3 86,8 93,5 112,6 126,5
Nominal cooling capacity kW 65 77,9 84,7 90,3 108,6 123,5
Absorbed power kW 21,78 25,57 27,53 30,12 36,05 40,54
Absorbed power kW 21,51 25,05 27,23 29,91 35,15 38,87
TCAIY-THAIY MODEL 270 280 290 2100 2115 2130
TCAITY-THAITY sound pressure dB(A) 52 53 53 53 55 56
TCAIQY-THAIQY sound pressure dB(A) 45 46 46 46 49 50
TCAITY-THAITY sound power dB(A) 84 85 85 85 87 88
TCAIQY-THAIQY sound power dB(A) 77 77,5 77,5 77,5 81 82
Scroll compressors n. 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1
Circuits n. 1 1 1 1 2 2
Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
DIMENSIONS AND WEIGHTS 270 280 290 2100 2115 2130
L – Width mm 3250 3250 3250 3250 3450 3450
H – Height mm 1540 1540 1540 1540 2000 2000
P – Depth mm 1210 1210 1210 1210 1520 1520
TCAITY weight kg 765 790 795 800 1125 1145
THAITY weight kg 880 915 920 925 1325 1345
SEASONAL ENERGY PERFORMANCE 270 280 290 2100 2115 2130
TCAITY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 69,8 82,6 90,3 97,9 117 130,4
SEER  (EN 14825) 4,59 4,69 4,65 4,6 4,27 4,27
ηs,c % 181 184 183 181 168 168
TCAIQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 67,8 80,8 87,7 93,4 111,4 125,5
SEER  (EN 14825) 4,49 4,58 4,49 4,45 4,11 4,12
ηs,c % 176 180 177 175 161 162
THAITY MODEL SEASONAL ENERGY PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 57 65 70 95 121 126
SCOP (EN 14825) 4,19 4,27 4,26 4,15 3,99 4,03
ηs % 165 168 167 163 156 158
Energy class A++ A++ A++ - - -
THAIQY MODEL SEASONAL ENERGY PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 54 63 69 93 111 133
SCOP (EN 14825) 4,04 4,17 4,11 4,06 3,88 3,96
ηs % 159 164 162 160 152 155
Energy class A++ A++ A++ - - -
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C
  • Air: 7°C, D.B. – 6°C W.B.- Water: 40/45°C.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • TCAIQY-THAIQY super-silenced versions.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
  • In Average climatic conditions, low temperature application (35°C)
  • Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.