Web code (TCAITE, TCAIQE): FPV44 Web code (TCAITO, TCAIQO): FPV46
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

FullPOWER ECO VFD (1+i) FullPOWER ECOA1 VFD (1+i)

TCAIT-TCAIQ 2390÷31380
Cooling capacity 377,7÷1380,2 kW

Packaged air-cooled water chillers with axial fans. Series with stepless semi-hermetic screw compressors and variable Vi with inverter adjustment and R1234ze or R515B refrigerant gas.

Features

Key features


1+i solution (stepless & inverter compressors)

Continuous power adjustment downt to 8%

SEER up to 5,24 with FIEC accessory (EC fans)

R1234ze and R515B (A1 category) ecological gases

Wide range of accessories

Integrated MASTER/SLAVE control


FullPOWER ECO VFD (1+i) FullPOWER ECOA1 VFD (1+i)

Description

Construction features

• Compressor: high energy efficiency semi-hermetic screw driven by fixed speed motor with linear capacity control and variable Vi regulated by inverter (down to 8% at part load), limited inrush start-up, complete with integral protection, casing heater, oil level sensor and shut-off valve on refrigerant gas outlet piping.
• Water side heat exchanger: dry expansion shell and tube exchanger with counterflow heat exchange, complete with closed cell polyurethane foam rubber insulation, water flow differential pressure switch and Victaulic fittings.
• Air side heat exchanger: with micro-channels.
• Fan: external rotor axial type electric fans equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed adjustment.
• Control: microprocessor electronic control.
• Structure: made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- display of cooling circuit high/low pressure;
- electronic expansion valve;
- oil level sensor;
- clock board;
- Master/Slave control up to 4 units in parallel;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version with oversized condensing section (TCAITE-TCAITO).
• Q - Super-silenced version complete with compressor technical compartment soundproofing, reduced speed fans and oversized condensing section (TCAIQE-TCAIQO).

Models

• TCAITE: high efficiency unit designed for cooling only with R1234ze gas.
• TCAIQE: super silenced unit designed for cooling only with R1234ze gas.
• TCAITO: high efficiency unit designed for cooling only with R515B gas.
• TCAIQO: super silenced unit designed for cooling only with R515B gas.

Factory fitted accessories

• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit.
• Freecooling module management.
• Condensing control with fans with EC motor.
• Condensing control with over-pressure fans (T version only).
• Power factor correction capacitors (cosφ > 0.94).
• Compressor circuit breaker switches.
• Electro-mechanical flow switch.
• EMC anti-disturbance filters.
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Soft starter.
• Soundproofed compressor box.
• Cooling circuit intake valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Coil protection nets or buffer panels.
• Microchannel coils with E-coating treatment, copper/aluminium, copper/copper, pre-painted copper/aluminium.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, electric pumps and heat exchangers for heat recovery if applicable.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Colour touch keypad (fitted on the machine or remotely) with 7” display.
• Spring anti-vibration mounts.
• Protective packaging.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCAITE-TCAITO-TCAIQE-TCAIQO MODEL 2390 2430 2510 2600 2700 2810 2900 2990 21100 21170 31260 31380
Nominal cooling capacity kW 389,7 434,6 508,5 604,4 699,5 807,4 896,4 989,5 1101,4 1169,3 1259,3 1380,2
Nominal cooling capacity kW 377,7 421,6 493,5 580,4 678,5 783,4 869,5 959,5 1068,4 1122,3 1221,3 1325,2
E.E.R. 3,25 3,14 3,26 3,28 3,26 3,15 3,2 3,2 3,15 3,24 3,17 3,21
E.E.R. 3,03 2,94 3,05 3,04 3,01 2,94 2,96 2,96 2,94 3 2,95 2,94
Absorbed power kW 119,9 138,4 156 184,3 214,6 256,3 280,1 309,2 349,7 360,9 397,3 430
Absorbed power kW 124,7 143,4 161,8 190,9 225,4 266,5 293,8 324,2 363,4 374,1 414 450,7
TCAITE-TCAITO-TCAIQE-TCAIQO MODEL 2390 2430 2510 2600 2700 2810 2900 2990 21100 21170 31260 31380
Sound pressure dB(A) 69 70 70 70 70 71 72 72 72 72 73 73
Sound pressure dB(A) 60 61 61 61 62 63 63 63 64 64 65 65
Sound power dB(A) 101 102 102 103 103 104 105 105 105 105 106 106
Sound power dB(A) 92 93 93 94 95 96 96 96 97 97 98 98
Screw compressors n. 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 1 1 inverter + 2 1 inverter + 2
Circuits n. 2 2 2 2 2 2 2 2 2 2 3 3
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 2390 2430 2510 2600 2700 2810 2900 2990 21100 21170 31260 31380
L – Width mm 4990 4990 6090 7250 7250 8350 9450 9450 10550 11650 11630 12730
H – Height mm 2480 2480 2480 2480 2480 2480 2480 2480 2480 2480 2480 2480
P – Depth mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260
TCAITE-TCAITO weight kg 3739 4085 4485 5069 5596 6034 6811 7059 7409 7797 9375 10065
TCAIQE-TCAIQO weight kg 4064 4410 4810 5499 6026 6464 7241 7489 7839 8227 9920 10610
SEASONAL ENERGY PERFORMANCE 2390 2430 2510 2600 2700 2810 2900 2990 21100 21170 31260 31380
TCAITE-TCAITO MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 389,7 434,6 508,5 604,4 699,5 807,4 896,4 989,5 1101,4 1169,3 1259,3 1380,2
SEER  (EN 14825) 5 4,95 5,02 5,03 4,99 5,01 5,02 5 5,01 5,02 5,04 5,1
ηs,c % 197 195 198 198 197 198 198 197 198 198 199 201
TCAIQE-TCAIQO MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 377,7 421,6 493,5 580,4 678,5 783,4 869,5 959,5 1068,4 1122,3 1221,3 1325,2
SEER  (EN 14825) 4,93 4,89 4,96 4,96 4,92 4,95 4,94 4,93 4,95 4,95 4,97 5,02
ηs,c % 194 193 195 195 194 195 195 194 195 195 196 198
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • TCAIQE-TCAIQO super-silenced versions.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.