Web code: WKE11
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

WinPACK HE-A

TCAEY-THAEY 2110÷4340
Cooling capacity 91,6÷345 kW
Heating capacity 110,5÷357 kW

Water chillers and packaged reversible air-cooled heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant.

Features

Key features


High energy efficiency chillers and heat pumps

Standard electronic expansion valve

Multi-purpose for systems with 2 pipes + DHW (with optional RC100)

Built-in MASTER/SLAVE control


WinPACK HE-A

Description

Construction features

• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• 2, 3 or 4 capacity steps with high efficiency at partial loads.
Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: featuring micro-channels or finned coil with copper pipes and aluminium fins depending on models/sizes.
• Fan: external rotor axial type electric fans with internal thermal protection, accident protection grilles.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- fan and compressor circuit breaker switches;
- display of cooling circuit high and low pressure;
- electronic expansion valve;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version with oversized condensing section (TCAETY-THAETY).
• Q - Super-silenced version complete with soundproofing compressor technical compartment, super-reduced speed fans and oversized condensing section (TCAEQY-THAEQY).

Models

• TCAETY: high efficiency unit designed for cooling only.
• TCAEQY: super silenced unit designed for cooling only.
• THAETY: heat pump unit.
• THAEQY: super silenced heat pump unit.

Factory fitted accessories

• Shell and tube evaporator.
• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with integrated buffer tank from 300 to 700 litres (depending on models) and single or double electric pump, complete with expansion tank, air vent valves, safety valve, and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit.
• Freecooling module management
• Condensing control.
• Condensing control with fans with EC motor (standard in Q versions).
• Condensing control with over-pressure fans.
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Optimised energy efficiency.
• Soft starter.
• Soundproofed compressor box or technical compartment soundproofing.
• Compressor soundproof enclosures.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Metal filters or coil protection nets.
• Microchannel coils with E-coating treatment, copper/copper or pre-painted copper/aluminium depending on the versions.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable.
• Buffer tank integrative heaters.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCAETY-TCAEQY MODEL 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
Nominal cooling capacity kW 110,5 121,5 138,4 156,4 175,4 200,3 223,2 241,3 276,3 309,1 345,1
Nominal cooling capacity kW 100,6 108,6 126,5 140,5 155,5 181,4 199,4 218,4 251,4 280,2 318,2
E.E.R. 3,13 3,1 3,13 3,11 3,1 3,11 3,1 3,1 3,1 3,1 3,1
E.E.R. 2,73 2,6 2,69 2,65 2,6 2,64 2,61 2,56 2,68 2,62 2,63
Absorbed power kW 35,3 39,2 44,2 50,3 56,6 64,4 72 77,8 88,8 99,7 111,3
Absorbed power kW 36,8 41,8 47 53 59,8 68,7 76,4 85 93,8 106,9 121
THAETY-THAEQY MODEL 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
Nominal heating capacity kW 114,5 124,5 141,6 161,6 181,7 204,8 233,9 249,8 282,8 321 357
Nominal heating capacity kW 110,5 118,5 136,5 153,6 171,6 194,7 221,8 236,7 266,7 301 341,9
C.O.P. 3,22 3,22 3,21 3,22 3,23 3,22 3,21 3,2 3,2 3,2 3,2
C.O.P. 3,28 3,29 3,27 3,26 3,26 3,23 3,26 3,12 3,11 2,95 3,08
Nominal cooling capacity kW 101,6 112,6 126,5 145,4 161,4 186,3 209,3 231,3 263,3 301,1 334,1
Nominal cooling capacity kW 91,6 100,6 118,6 130,6 144,5 169,5 187,4 206,5 238,4 270,3 302,3
Absorbed power kW 35,6 38,7 44,1 50,2 56,3 63,6 72,9 78,1 88,4 100,3 111,6
Absorbed power kW 33,7 36 41,7 47,1 52,6 60,3 68 75,9 85,8 102 111
TCAETY-TCAEQY-THAETY-THAEQY MODEL 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
TCAETY sound pressure dB(A) 55 56 57 57 58 59 59 58 60 60 62
THAETY sound pressure dB(A) 53 54 55 55 56 57 57 58 60 60 62
TCAEQY-THAEQY sound pressure dB(A) 47 47 48 48 49 50 50 51 53 53 54
TCAETY sound power dB(A) 87 88 89 89 90 91 91 90 92 92 94
THAETY sound power dB(A) 85 86 87 87 88 89 89 90 92 92 94
TCAEQY-THAEQY sound power dB(A) 79 79 80 80 81 82 82 83 85 85 86
Scroll compressors/steps n. 2/3 2/3 2/2 2/3 2/2 2/3 2/2 4/4 4/4 4/4 4/4
Circuits n. 1 1 1 1 1 1 1 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
L – Width mm 3600 3600 3600 3600 4550 4550 4550 4800 4800 5300 5300
H – Height mm 2440 2440 2440 2440 2440 2440 2440 2030 2030 2030 2030
P – Depth mm 1350 1350 1350 1350 1350 1350 1350 2090 2090 2090 2090
TCAETY weight kg 1090 1100 1110 1130 1280 1300 1320 2290 2390 2520 2640
TCAEQY weight kg 1250 1260 1270 1290 1440 1460 1480 2420 2520 2650 2770
THAETY weight kg 1380 1410 1420 1500 1670 1690 1780 2470 2570 2720 2840
THAEQY weight kg 1420 1450 1460 1540 1710 1730 1820 2600 2700 2850 2970
SEASONAL ENERGY PERFORMANCE 2110 2120 2140 2150 2170 2200 2220 4240 4270 4310 4340
TCAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 110,5 121,5 138,4 156,4 175,4 200,3 223,2 241,3 276,2 309,1 345
SEER  (EN 14825) 4,36 4,39 4,21 4,35 4,38 4,34 4,34 4,4 4,4 4,4 4,38
ηs,c % 171 173 165 171 172 170 171 173 173 173 172
TCAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 100,6 108,6 126,5 140,5 155,5 181,4 199,4 218,4 251,4 280,2 318,2
SEER  (EN 14825) 4,3 4,13 4,15 4,23 4,12 4,24 4,13 4,21 4,3 4,31 4,26
ηs,c % 169 162 163 166 162 167 162 166 169 170 167
THAETY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 96 104 118 135 150 173 201 211 242 273 302
SCOP (EN 14825) 3,53 3,51 3,75 3,49 3,76 3,39 3,57 3,64 3,62 3,64 3,63
ηs % 138 138 147 137 148 133 140 142 142 143 142
THAEQY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 91 98 113 127 141 165 190 199 227 254 288
SCOP (EN 14825) 3,62 3,61 3,84 3,59 3,88 3,53 3,65 3,56 3,54 3,37 3,52
ηs % 142 141 151 141 152 138 143 139 139 132 138
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C.
  • Air: 7°C, D.B. 6°C W.B.- Water: 40/45°C.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • TCAEQY-THAEQY super-silenced versions.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
  • In Average climatic conditions, low temperature application (35°C)
  • Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: TIF
Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.