Web code: WPE11
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

WinPOWER HE-A

TCAEY 4385÷8920 / THAEY 4385÷6700
Cooling capacity 354,2÷916,8 kW
Heating capacity 383,3÷698,9 kW

Air cooled water chillers and reversible heat pumps with axial fans. Range with scroll hermetic compressors and R410A refrigerant.

Features

Key features


High energy efficiency chillers

Extended operating limits

Up to 6 capacity steps

Multi-purpose for systems with 2 pipes + DHW (with optional RC100)

Built-in MASTER/SLAVE control


WinPOWER HE-A

Description

Construction features

• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• Up to 6 capacity steps with high efficiency at partial loads.
• Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation, water flow differential pressure switch and Victaulic fittings.
• Air side heat exchanger: featuring micro-channels (TCAEY) or finned coil with copper pipes and aluminium fins (THAEY).
• Fan: external rotor axial type electric fans, equipped with internal thermal protection, accident protection grilles and a proportional electronic device for continuous fan rotation speed regulation (T version; fans with an EC motor are standard in the Q version).
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- fan and compressor circuit breaker switches;
- display of cooling circuit high and low pressure;
- electronic expansion valve;
- clock board;
- Master/Slave control up to 4 units in parallel;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version with oversized condensing section (TCAETY - THAETY).
• Q - Super-silenced version complete with compressor technical compartment soundproofing, reduced speed fans and oversized condensing section (TCAEQY-THAEQY).

Models

• TCAETY: high efficiency unit designed for cooling only.
• TCAEQY: super silenced unit designed for cooling only.
• THAETY: high efficiency heat pump unit.
• THAEQY: super silenced heat pump unit.

Factory fitted accessories

• Shell and tube evaporator.
• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 700 or 1000 litre integrated buffer tank (depending on size) and single or double electric pump, complete with expansion tank, air vent valves, safety valve and water side pressure gauge.
• Inverter pump control for unit start-up (TCAETY, TCAEQY, THAEQY).
• Desuperheater.
• 100% heat recovery unit.
• Freecooling module management.
• Condensing control with fans with EC motor (standard in Q versions).
• Condensing control with over-pressure fans.
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Soft starter.
• Soundproofed compressor box or Compressor box and soundproofed cooling circuit (THAEY).
• Compressor soundproof enclosures.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves
• Metal filters (THAEY) or coil protection nets.
• Microchannel coils with E-coating treatment, copper/copper or pre-painted copper/aluminium depending on the versions.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCAETY-TCAEQY MODEL 4385 4415 4460 5525 6570 6625 6665 6700 7760 8820 8870 8920
Nominal cooling capacity kW 385 414 460,8 524,5 569,5 623,1 665,3 695,2 758,3 819,9 870 916,8
Nominal cooling capacity kW 372,1 400 440,9 492,7 535,7 585,4 634,5 663,5 728,6 790,1 830,2 867,6
E.E.R. 3,24 3,16 3,13 3,19 3,17 3,1 3,16 3,13 3,14 3,15 3,14 3,13
E.E.R. 3,12 2,97 2,9 2,98 2,89 2,7 2,96 2,91 2,93 2,93 2,9 2,86
Absorbed power kW 118,9 131,1 147,3 164,5 179,7 201 210,6 222,2 241,5 260,3 277,1 293
Absorbed power kW 119,3 134,7 152 165,3 185,4 216,8 214,4 228 248,7 269,7 286,3 303,4
TCAETY-TCAEQY MODEL 4385 4415 4460 5525 6570 6625 6665 6700 7760 8820 8870 8920
TCAETY sound pressure dB(A) 62,5 63,5 64,5 64,5 64,5 64,5 65,5 65,5 65,5 65,5 66 67
TCAEQY sound pressure dB(A) 54,5 54,5 55,5 55,5 55,5 55,5 56,5 57,5 58 58 59 60
TCAETY sound power dB(A) 95 96 97 97 97 97 98 98 98 98 99 100
TCAEQY sound power dB(A) 87 87 88 88 88 88 89 90 91 91 92 93
Scroll compressors/steps n. 4/4 4/4 4/4 5/5 6/6 6/6 6/6 6/6 7/6 8/6 8/6 8/6
Circuits n. 2 2 2 2 2 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 4385 4415 4460 5525 6570 6625 6665 6700 7760 8820 8870 8920
L – Width mm 4840 4840 4840 5940 5940 5940 7100 7100 8250 9350 9350 9350
H – Height mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450
P – Depth mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260
TCAETY weight kg 2440 2460 2510 2980 3200 3210 3715 3740 4250 4650 4750 4770
TCAEQY weight kg 2715 2735 2785 3300 3565 3575 4080 4105 4655 5105 5205 5225
THAETY-THAEQY MODEL 4385 4415 4460 5525 6570 6625 6665 6700
Nominal heating capacity kW 386,9 425 464,2 520,4 571,5 626,8 662,6 698,9
Nominal heating capacity kW 383,3 420,8 458,3 512,5 556,2 622,1 656,1 687,4
C.O.P. 3,2 3,2 3,2 3,2 3,2 3,2 3,21 3,22
C.O.P. 3,33 3,3 3,3 3,28 3,28 3,29 3,33 3,32
Nominal cooling capacity kW 359,2 399 439,9 498,7 538,6 584,4 633,5 660,3
Nominal cooling capacity kW 354,2 385,1 421,1 474,8 507,8 546,6 606,7 631,5
E.E.R. 2,97 2,96 2,95 3,02 2,95 2,9 3,02 2,97
E.E.R. 2,91 2,82 2,75 2,84 2,72 2,53 2,8 2,78
Absorbed power kW 121 132,9 145,1 162,7 178,6 195,9 206,5 217,1
Absorbed power kW 115,1 127,5 138,9 156,3 169,6 189,1 197 207
THAETY-THAEQY MODEL 4385 4415 4460 5525 6570 6625 6665 6700
THAETY sound pressure dB(A) 62,5 63,5 64,5 64,5 64,5 64,5 65,5 65,5
THAEQY sound pressure dB(A) 54,5 54,5 55,5 55,5 55,5 55,5 56,5 57,5
THAETY sound power dB(A) 95 96 97 97 97 97 98 98
THAEQY sound power dB(A) 87 87 88 88 88 88 89 90
Scroll compressors/steps n. 4/4 4/4 4/4 5/5 6/6 6/6 6/6 6/6
Circuits n. 2 2 2 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 4385 4415 4460 5525 6570 6625 6665 6700
L – Width mm 4840 4840 4840 5940 5940 5940 6840 6840
H – Height mm 2450 2450 2450 2450 2450 2450 2450 2450
P – Depth mm 2260 2260 2260 2260 2260 2260 2260 2260
THAETY weight kg 3030 3200 3250 3830 4040 4070 4680 4710
THAEQY weight kg 3395 3565 3615 4310 4520 4550 5210 5240
SEASONAL ENERGY PERFORMANCE 4385 4415 4460 5525 6570 6625 6665 6700 7760 8820 8870 8920
TCAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 385 414 460,8 524,5 569,5 623,1 665,3 695,2 758,3 819,9 870 916,8
SEER  (EN 14825) 4,78 4,75 4,77 4,76 4,78 4,77 4,76 4,77 4,77 4,76 4,76 4,77
ηs,c % 188 187 188 187 188 188 187 188 188 188 187 188
TCAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 372,1 400 440,9 492,7 535,7 585,4 634,5 663,5 728,6 790,1 830,2 867,6
SEER  (EN 14825) 4,91 4,91 4,89 4,91 4,86 4,87 4,88 4,9 4,85 4,86 4,88 4,87
ηs,c % 193 193 192 193 191 192 192 193 191 191 192 192
THAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW - - 439,9 498,7 538,6 584,3 633,5 660,3 - - - -
SEER  (EN 14825) - - 4,68 4,68 4,66 4,67 4,65 4,68 - - - -
ηs,c % - - 184 184 184 184 183 184 - - - -
THAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW - - 421,1 474,8 507,8 546,6 606,7 631,5 - - - -
SEER  (EN 14825) - - 4,81 4,81 4,82 4,81 4,83 4,84 - - - -
ηs,c % - - 189 189 190 189 190 191 - - - -
THAETY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 354 388 - - - - - - - - - -
SCOP (EN 14825) 3,53 3,56 - - - - - - - - - -
ηs % 138 139 - - - - - - - - - -
THAEQY MODEL SEASONAL PERFORMANCE IN HEATING MODE
Pdesignh (EN 14825) kW 350 385 - - - - - - - - - -
SCOP (EN 14825) 3,8 3,8 - - - - - - - - - -
ηs % 149 149 - - - - - - - - - -
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C.
  • Air: 7°C, D.B. 6°C W.B.- Water: 40/45°C.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • TCAEQY super-silenced versions.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
  • In Average climatic conditions, low temperature application (35°C)
  • Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Format: TIF
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.