WinPACK-R HE-A
TCAETY-TCAEQY 4235÷4370Packaged air-cooled water chillers with axial fans. Range with scroll hermetic compressors and R410A refrigerant.
Key features
High energy efficiency compact chillers
Standard electronic expansion valve
Integrated MASTER/SLAVE control
Description
Construction features
• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• 4 capacity steps with high efficiency at partial loads.
Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: with micro-channels.
• Fan: external rotor axial type electric fans with internal thermal protection, accident protection grilles.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- fan and compressor circuit breaker switches;
- display of cooling circuit high and low pressure;
- electronic expansion valve;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).
Versions
• T - High efficiency version with oversized condensing section.
• Q - Super-silenced version complete with compressor technical compartment soundproofing, super-reduced speed fans and oversized condensing section.
Models
• TCAETY: high efficiency unit designed for cooling only.
• TCAEQY: super silenced unit designed for cooling only.
Factory fitted accessories
• Shell and tube evaporator.
• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 700 - 1000 litre integrated buffer tank (depending on models) and single or double electric pump, complete with expansion tank, air vent valves, safety valve and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit.
• Freecooling module management.
• Condensing control.
• Condensing control with fans with EC motor (standard in Q versions).
• Condensing control with over-pressure fans.
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Optimised energy efficiency.
• Soft starter.
• Soundproofed compressor box.
• Compressor soundproof enclosures.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Coil protection nets.
• Micro-channel coils with E-coating treatment.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Anti-vibration mounts.
Separately supplied accessories
• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.
Technical data
TCAETY-TCAEQY MODEL | 4235 | 4260 | 4290 | 4330 | 4370 | ||||
❶ | Nominal cooling capacity | kW | 235,3 | 261,3 | 292,2 | 334 | 372 | ||
❶ | Nominal cooling capacity | kW | 221,4 | 243,4 | 269,4 | 312,1 | 343,1 | ||
❶ | E.E.R. | 3,27 | 3,2 | 3,12 | 3,19 | 3,15 | |||
❶ | E.E.R. | 3,12 | 2,88 | 2,68 | 2,89 | 2,75 | |||
❶ | Absorbed power | kW | 72 | 81,7 | 93,7 | 104,7 | 118,1 | ||
❶ | Absorbed power | kW | 71 | 84,5 | 100,5 | 108 | 124,8 | ||
TCAETY-TCAEQY MODEL | 4235 | 4260 | 4290 | 4330 | 4370 | ||||
❷ | TCAETY sound pressure | dB(A) | 59 | 60 | 61 | 62 | 63 | ||
❷ | TCAEQY sound pressure | dB(A) | 50 | 51 | 52 | 53 | 54 | ||
❸ | TCAETY sound power | dB(A) | 91 | 92 | 93 | 94 | 95 | ||
❸ | TCAEQY sound power | dB(A) | 82 | 83 | 84 | 85 | 86 | ||
Scroll compressors/steps | n. | 4/4 | 4/4 | 4/4 | 4/4 | 4/4 | |||
Circuits | n. | 2 | 2 | 2 | 2 | 2 | |||
Electrical supply | V-ph-Hz | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | 400-3-50 | |||
DIMENSIONS AND WEIGHTS | 4235 | 4260 | 4290 | 4330 | 4371 | ||||
L – Width | mm | 3650 | 3650 | 3650 | 4750 | 4750 | |||
H – Height | mm | 2450 | 2450 | 2450 | 2450 | 2450 | |||
P – Depth | mm | 2260 | 2260 | 2260 | 2260 | 2260 | |||
❹ | TCAETY weight | kg | 1620 | 1820 | 1985 | 2265 | 2310 | ||
❹ | TCAEQY weight | kg | 1895 | 2095 | 2260 | 2540 | 2585 | ||
SEASONAL ENERGY PERFORMANCE | 4235 | 4260 | 4290 | 4330 | 4370 | ||||
TCAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||
① | Pdesignc (EN 14825) | kW | 235,3 | 261,3 | 292,2 | 334 | 372 | ||
① | SEER (EN 14825) | 4,45 | 4,46 | 4,44 | 4,6 | 4,54 | |||
② | ηs,c | % | 175 | 175 | 175 | 181 | 179 | ||
TCAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE | |||||||||
① | Pdesignc (EN 14825) | kW | 221,4 | 243,4 | 269,4 | 312,1 | 343,1 | ||
① | SEER (EN 14825) | 4,39 | 4,34 | 4,32 | 4,43 | 4,42 | |||
② | ηs,c | % | 173 | 171 | 170 | 174 | 174 | ||
- Data at the following conditions:
- ❶ Air: 35°C – Water: 12/7°C.
- ❷ In open field (Q = 2) at 10 m from the unit.
- ❸ Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
- ❹ Weight referred to the unit without load and not accessorised.
- ■ TCAEQY super-silenced versions.
- Performance according to EN 14511.
- ① Low temperature application (7°C)
- ② Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Images
Request information about this product
Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.