Web code: WKE21
CHILLERS HEAT PUMPS AIR-cooled AXIAL fans

WinPACK-R HE-A

TCAETY-TCAEQY 4235÷4370
Cooling capacity 221,4÷372 kW

Packaged air-cooled water chillers with axial fans. Range with scroll hermetic compressors and R410A refrigerant.

Features

Key features


High energy efficiency compact chillers

Standard electronic expansion valve

Integrated MASTER/SLAVE control


WinPACK-R HE-A

Description

Construction features

• Compressor: scroll type, rotary, hermetic complete with thermal protection and casing heater.
• 4 capacity steps with high efficiency at partial loads.
Water side heat exchanger: with stainless steel plates, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
• Air side heat exchanger: with micro-channels.
• Fan: external rotor axial type electric fans with internal thermal protection, accident protection grilles.
• Control: microprocessor electronic control with Adaptive Function Plus logic.
• Structure: load-bearing structure made of galvanised and painted steel plate with polyester powder coating.
• The unit is also complete with:
- fan and compressor circuit breaker switches;
- display of cooling circuit high and low pressure;
- electronic expansion valve;
- Master/Slave control up to 4 units in parallel;
- clock board;
- control of Variable Primary Flow (VPF_R).

Versions

• T - High efficiency version with oversized condensing section.
• Q - Super-silenced version complete with compressor technical compartment soundproofing, super-reduced speed fans and oversized condensing section.

Models

• TCAETY: high efficiency unit designed for cooling only.
• TCAEQY: super silenced unit designed for cooling only.

Factory fitted accessories

• Shell and tube evaporator.
• PUMP with single or double electric pump, one of which automatic in standby. The electric pumps are available in the low or high head versions.
• TANK&PUMP with 700 - 1000 litre integrated buffer tank (depending on models) and single or double electric pump, complete with expansion tank, air vent valves, safety valve and water side pressure gauge.
• Inverter pump control for unit start-up.
• Desuperheater.
• 100% heat recovery unit.
• Freecooling module management.
• Condensing control.
• Condensing control with fans with EC motor (standard in Q versions).
• Condensing control with over-pressure fans.
• Power factor correction capacitors (cosφ > 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameter measuring device.
• Optimised energy efficiency.
• Soft starter.
• Soundproofed compressor box.
• Compressor soundproof enclosures.
• Cooling circuit outlet and inlet valves.
• Refrigerant leak detector.
• Cooling circuit high and low pressure gauges.
• Double safety valves.
• Coil protection nets.
• Micro-channel coils with E-coating treatment.
• Control of min/max power supply voltage.
• Digital input for double set-point.
• 4-20 mA analogue signal for shifting set-point.
• Evaporator antifreeze heater, electrical panel, buffer tank, electric pumps and heat exchangers for heat recovery, if applicable.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Anti-vibration mounts.

Separately supplied accessories

• Remote keypad with display.
• Thermostat with display.
• Rhoss supervisors for unit monitoring and remote management.
• Rhoss sequencer for integrated management of multiple chillers.

Technical data

TCAETY-TCAEQY MODEL 4235 4260 4290 4330 4370
Nominal cooling capacity kW 235,3 261,3 292,2 334 372
Nominal cooling capacity kW 221,4 243,4 269,4 312,1 343,1
E.E.R. 3,27 3,2 3,12 3,19 3,15
E.E.R. 3,12 2,88 2,68 2,89 2,75
Absorbed power kW 72 81,7 93,7 104,7 118,1
Absorbed power kW 71 84,5 100,5 108 124,8
TCAETY-TCAEQY MODEL 4235 4260 4290 4330 4370
TCAETY sound pressure dB(A) 59 60 61 62 63
TCAEQY sound pressure dB(A) 50 51 52 53 54
TCAETY sound power dB(A) 91 92 93 94 95
TCAEQY sound power dB(A) 82 83 84 85 86
Scroll compressors/steps n. 4/4 4/4 4/4 4/4 4/4
Circuits n. 2 2 2 2 2
Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
DIMENSIONS AND WEIGHTS 4235 4260 4290 4330 4371
L – Width mm 3650 3650 3650 4750 4750
H – Height mm 2450 2450 2450 2450 2450
P – Depth mm 2260 2260 2260 2260 2260
TCAETY weight kg 1620 1820 1985 2265 2310
TCAEQY weight kg 1895 2095 2260 2540 2585
SEASONAL ENERGY PERFORMANCE 4235 4260 4290 4330 4370
TCAETY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 235,3 261,3 292,2 334 372
SEER  (EN 14825) 4,45 4,46 4,44 4,6 4,54
ηs,c % 175 175 175 181 179
TCAEQY MODEL SEASONAL PERFORMANCE IN COOLING MODE
Pdesignc (EN 14825) kW 221,4 243,4 269,4 312,1 343,1
SEER  (EN 14825) 4,39 4,34 4,32 4,43 4,42
ηs,c % 173 171 170 174 174
  • Data at the following conditions:
  • Air: 35°C – Water: 12/7°C.
  • In open field (Q = 2) at 10 m from the unit.
  • Total sound power level in dB(A) based on measurements carried out in accordance with regulation UNI EN-ISO 9614.
  • Weight referred to the unit without load and not accessorised.
  • TCAEQY super-silenced versions.
  • Performance according to EN 14511.
  • Low temperature application (7°C)
  • Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281)

Manuals

To view all the documents, log in to the reserved area

Technical notes

To view all the documents, log in to the reserved area

Documents

To view all the documents, log in to the reserved area

Images

Format: tif
Request information about this product









    Find an agent or a reseller.

    Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.