Fan coils
COVER for YARDYInstallation solutions with formwork and covering panels on the wall or on the ceiling
Key features
Concealed fan coil installation
Wall-flush aesthetic cover panel in white RAL 9003
Recessed wall or false ceiling installation
Description
Yardy EV3 and Yardy-I EV3 - Versions
• IVP - Recessed vertical unit equipped with lower air inlet and upper delivery for wall mounting installation.
• IXP - Horizontal/vertical unit equipped with lower air inlet and upper delivery for false ceiling or recessed wall installation.
Yardy-ID2 and YardyDUCT2 - Version
• CXP - Ducted recessed unit for horizontal or vertical installation (with lower return and upper delivery).
Models
Yardy-I EV3: 20, 24, 30, 34, 45, 48
Yardy EV3: 20, 24, 25, 30, 34, 40, 45, 48
Yardy-ID2: 40, 48
YardyDUCT2: 40, 48
Construction set-ups
Type of unit
2T - Single main coil.
4T - Double main coil and additional.
ACCESSORIES for Yardy COVER
➔ Formwork for recessed wall or false ceiling installation
➔ Aesthetic panel for wall mounted formwork, colour matt white RAL 9003, with air delivery and return grille for wall mounting installation (IVP and IXP version only).
➔ Aesthetic panel for formwork, colour matt white RAL 9003, with air inlet grille for wall mounting or ceiling installation
➔ Delivery nozzle made of aluminium, with a double row of adjustable fins
CONTROLS for Yardy COVER
STANDARD controls
For wall mounting installation
➔ Panel with speed and summer/winter switch.
➔ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve control and electrical resistance.
➔ Minimum temperature thermostat (for installation on machine).
➔ Electronic panel with automatic summer/winter switching for 2-pipe systems.
➔ Electronic panel with automatic summer/winter switching and automatic speed adjustment for 2-pipe systems with electrical resistance or 4-pipe systems.
➔ Electronic panel with display and RS485 serial interface, semi-recessed in wall.
Advanced LIT-TOUCH controls
➔ Flush LIT-Touch control panel in glossy black or pearl white for wall mounting installation.
➔ Wall mounted LIT-Touch remote control and receiver with air temperature probe and operation LED.
For on board installation
➔❖ LIT-Touch electronic control for 2-pipe systems, with 2 pipes with electrical resistance or 4 pipes, complete with minimum water temperature probe, ON/OFF valve control and integrated master/slave function up to a total of 15 units.
➔❖ Additional board with 2 digital outputs that can be configured.
➔❖ On board air temperature probe.
➔❖ RS485 serial board for serial communication with other devices (Modbus RTU protocol).
Technical data
YARDY-I EV3 IVP-IXP | 20 | 24 | 30 | 34 | 45 | 48 | ||||||||||||||
❶ | Total cooling capacity [EN1397] | MAX | kW | E | 1,86 | 2,24 | 2,97 | 3,37 | 4,11 | 4,6 | ||||||||||
MED | kW | E | 1,44 | 1,68 | 2,33 | 2,75 | 3,05 | 3,49 | ||||||||||||
MIN | kW | E | 0,75 | 0,8 | 1,08 | 1,34 | 1,53 | 1,73 | ||||||||||||
❷ | Heating capacity (45°C) [EN1397] | MAX | kW | E | 2,1 | 2,18 | 3,27 | 3,41 | 4,47 | 4,65 | ||||||||||
MED | kW | E | 1,48 | 1,57 | 2,52 | 2,6 | 3,13 | 3,27 | ||||||||||||
MIN | kW | E | 0,77 | 0,81 | 1,2 | 1,26 | 1,5 | 1,57 | ||||||||||||
❸ | Heating capacity (50°C) | MAX | kW | E | 2,47 | 2,6 | 3,87 | 4,07 | 5,3 | 5,54 | ||||||||||
MED | kW | E | 1,77 | 1,88 | 2,99 | 3,14 | 3,74 | 3,93 | ||||||||||||
MIN | kW | E | 0,92 | 0,97 | 1,42 | 1,52 | 1,81 | 1,9 | ||||||||||||
❹ | Heating capacity (70°C) [EN1397] | MAX | kW | 4,2 | 4,36 | 6,56 | 6,85 | 8,96 | 9,31 | |||||||||||
MED | kW | 2,98 | 3,14 | 5,06 | 5,26 | 6,28 | 6,56 | |||||||||||||
MIN | kW | 1,56 | 1,64 | 2,44 | 2,56 | 3,06 | 3,19 | |||||||||||||
❺ | Heating capacity of additional coil (65°C) [EN1397] | MAX | kW | E | 1,95 | 2,08 | 2,94 | 2,8 | 3,36 | 3,2 | ||||||||||
MED | kW | E | 1,66 | 1,6 | 2,34 | 2,22 | 2,84 | 2,7 | ||||||||||||
MIN | kW | E | 0,87 | 0,83 | 1,3 | 1,23 | 1,53 | 1,46 | ||||||||||||
❹ | Heating capacity of additional coil (70°C) [EN1397] | MAX | kW | E | 2,21 | 2,36 | 3,33 | 3,17 | 3,83 | 3,64 | ||||||||||
MED | kW | E | 1,92 | 1,84 | 2,65 | 2,52 | 3,3 | 3,15 | ||||||||||||
MIN | kW | E | 1,01 | 0,96 | 1,48 | 1,41 | 1,79 | 1,7 | ||||||||||||
Air flow speed | MAX | m³/h | 331 | 331 | 523 | 523 | 645 | 645 | ||||||||||||
MED | m³/h | 230 | 230 | 400 | 400 | 450 | 450 | |||||||||||||
MIN | m³/h | 97 | 97 | 167 | 167 | 198 | 198 | |||||||||||||
Sound power | MAX | dB(A) | E | 48 | 48 | 50 | 50 | 51 | 51 | |||||||||||
MED | dB(A) | E | 40 | 40 | 43 | 43 | 42 | 42 | ||||||||||||
MIN | dB(A) | E | 29 | 29 | 29 | 29 | 29 | 29 | ||||||||||||
❻ | Sound pressure | MAX | dB(A) | 39 | 39 | 41 | 41 | 42 | 42 | |||||||||||
MED | dB(A) | 31 | 31 | 34 | 34 | 33 | 33 | |||||||||||||
MIN | dB(A) | 20 | 20 | 20 | 20 | 20 | 20 | |||||||||||||
Absorbed power | MAX | W | E | 23 | 25 | 26 | 28 | 39 | 42 | |||||||||||
MED | W | E | 13 | 14 | 15 | 16 | 14 | 15 | ||||||||||||
MIN | W | E | 6 | 6 | 6 | 6 | 7 | 8 | ||||||||||||
Electrical supply | V-ph-Hz | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | |||||||||||||
DIMENSIONS AND WEIGHT | 20 | 24 | 30 | 34 | 45 | 48 | ||||||||||||||
L – IVP-IXP Width | mm | 550 | 550 | 750 | 750 | 950 | 950 | |||||||||||||
H – IVP-IXP Height | mm | 545 | 545 | 545 | 545 | 545 | 545 | |||||||||||||
P – IVP-IXP Depth | mm | 212 | 212 | 212 | 212 | 212 | 212 | |||||||||||||
IVP-IXP Weight | kg | 16,5 | 17 | 20,5 | 21,5 | 25,5 | 27 | |||||||||||||
COVER for Yardy-I | 20 | 24 | 30 | 34 | 45 | 48 | ||||||||||||||
KCASE formwork | WxHxD | mm | 920x790x225 | 920x790x225 | 1125x790x225 | 1125x790x225 | 1325x790x225 | 1325x790x225 | ||||||||||||
KCASE formwork | Weight | kg | 13 | 13 | 15 | 15 | 17 | 17 | ||||||||||||
KPVCASE – KPXCASE panel | WxHxD | mm | 975x820x10 | 975x820x10 | 1175x820x10 | 1175x820x10 | 1375x820x10 | 1375x820x10 | ||||||||||||
KPVCASE – KPXCASE panel | Weight | kg | 9 | 9 | 10 | 10 | 11 | 11 | ||||||||||||
KGMD delivery nozzle | WxHxD | mm | 555x205x6 | 555x205x6 | 755x205x6 | 755x205x6 | 955x205x6 | 955x205x6 | ||||||||||||
YARDY EV3 IVP-IXP | 20 | 24 | 25 | 30 | 34 | 40 | 45 | 48 | ||||||||||||
❶ | Total cooling capacity [EN1397] | VI | kW | 1,98 | 2,2 | •E | 2,5 | •E | 3,21 | 3,28 | •E | 3,72 | 4,26 | •E | 4,76 | •E | ||||
V | kW | 1,76 | •E | 2,1 | 2,24 | 2,8 | •E | 3,05 | 3,36 | •E | 3,84 | 4,46 | ||||||||
IV | kW | 1,54 | 1,87 | •E | 2,02 | •E | 2,57 | 2,81 | •E | 2,84 | 3,31 | •E | 3,57 | •E | ||||||
III | kW | 1,37 | •E | 1,68 | 1,69 | 2,46 | •E | 2,55 | 2,63 | •E | 2,99 | 3,35 | ||||||||
II | kW | 1,18 | 1,45 | •E | 1,62 | •E | 2,07 | 2,25 | •E | 2,47 | 2,81 | 3,11 | ||||||||
I | kW | 1,13 | •E | 1,35 | 1,38 | 1,78 | •E | 1,98 | 2,06 | •E | 2,49 | •E | 2,85 | •E | ||||||
❷ | Heating capacity (45°C) [EN1397] | VI | kW | 2,26 | 2,36 | •E | 2,97 | •E | 3,59 | 3,77 | •E | 4,37 | 4,68 | •E | 4,89 | •E | ||||
V | kW | 1,97 | •E | 2,04 | 2,68 | 3,29 | •E | 3,45 | 3,79 | •E | 4,27 | 4,45 | ||||||||
IV | kW | 1,62 | 1,73 | •E | 2,3 | •E | 2,85 | 2,98 | •E | 3,22 | 3,47 | •E | 3,64 | •E | ||||||
III | kW | 1,47 | •E | 1,52 | 1,94 | 2,66 | •E | 2,79 | 2,98 | •E | 3,21 | 3,34 | ||||||||
II | kW | 1,26 | 1,44 | •E | 1,85 | •E | 2,26 | 2,35 | •E | 2,77 | 2,81 | 2,93 | ||||||||
I | kW | 1,24 | •E | 1,27 | 1,57 | 2,02 | •E | 2,2 | 2,52 | •E | 2,59 | •E | 2,69 | •E | ||||||
❸ | Heating capacity (50°C) | VI | kW | 2,65 | 2,78 | •E | 3,47 | •E | 4,21 | 4,42 | •E | 5,11 | 5,51 | •E | 5,79 | •E | ||||
V | kW | 2,31 | •E | 2,43 | 3,14 | 3,85 | •E | 4,04 | 4,45 | •E | 5,03 | 5,28 | ||||||||
IV | kW | 1,91 | 2,06 | •E | 2,71 | •E | 3,36 | 3,53 | •E | 3,79 | 4,11 | •E | 4,32 | •E | ||||||
III | kW | 1,74 | •E | 1,83 | 2,28 | 3,14 | •E | 3,3 | 3,5 | •E | 3,79 | 3,98 | ||||||||
II | kW | 1,49 | 1,72 | •E | 2,18 | •E | 2,67 | 2,8 | •E | 3,26 | 3,35 | 3,52 | ||||||||
I | kW | 1,46 | •E | 1,53 | 1,84 | 2,37 | •E | 2,59 | 2,93 | •E | 3,08 | •E | 3,23 | •E | ||||||
❹ | Heating capacity (70°C) [EN1397] | VI | kW | 4,52 | 4,71 | • | 5,94 | • | 7,17 | 7,54 | • | 8,75 | 9,34 | • | 9,77 | • | ||||
V | kW | 3,93 | • | 4,08 | 5,37 | 6,58 | • | 6,88 | 7,59 | • | 8,53 | 8,88 | ||||||||
IV | kW | 3,23 | 3,45 | • | 4,61 | • | 5,71 | 5,97 | • | 6,46 | 6,93 | • | 7,27 | • | ||||||
III | kW | 2,95 | • | 3,06 | 3,88 | 5,32 | • | 5,61 | 5,96 | • | 6,4 | 6,69 | ||||||||
II | kW | 2,54 | 2,89 | • | 3,71 | • | 4,53 | 4,76 | • | 5,57 | 5,63 | 5,89 | ||||||||
I | kW | 2,5 | • | 2,57 | 3,15 | 4,06 | • | 4,44 | 5,05 | • | 5,19 | • | 5,42 | • | ||||||
❺ | Heating capacity of additional coil (65°C) [EN1397] | VI | kW | 2,09 | 1,78 | •E | 2,7 | •E | 3,2 | 3,05 | •E | 3,68 | 3,5 | •E | 3,34 | •E | ||||
V | kW | 1,92 | •E | 1,69 | 2,61 | 2,69 | •E | 2,56 | 2,94 | •E | 3,38 | 3,22 | ||||||||
IV | kW | 1,81 | 1,46 | •E | 2,28 | •E | 2,61 | 2,48 | •E | 2,9 | 2,96 | •E | 2,82 | •E | ||||||
III | kW | 1,51 | •E | 1,33 | 2 | 2,28 | •E | 2,17 | 2,81 | •E | 2,79 | 2,65 | ||||||||
II | kW | 1,4 | 1,2 | •E | 1,84 | •E | 2,15 | 2,04 | •E | 2,76 | 2,74 | 2,6 | ||||||||
I | kW | 1,29 | •E | 1,16 | 1,69 | 1,93 | •E | 1,83 | 2,62 | •E | 2,21 | •E | 2,15 | •E | ||||||
❹ | Heating capacity of additional coil (70°C) [EN1397] | VI | kW | 2,37 | 2,01 | •E | 3,06 | •E | 3,62 | 3,45 | •E | 4,18 | 3,98 | •E | 3,79 | •E | ||||
V | kW | 2,2 | •E | 1,93 | 2,95 | 3,04 | •E | 2,9 | 3,46 | •E | 3,84 | 3,66 | ||||||||
IV | kW | 2,09 | 1,7 | •E | 2,59 | •E | 2,95 | 2,8 | •E | 3,36 | 3,46 | •E | 3,27 | •E | ||||||
III | kW | 1,75 | •E | 1,56 | 2,27 | 2,58 | •E | 2,46 | 3,33 | •E | 3,25 | 3,07 | ||||||||
II | kW | 1,63 | 1,4 | •E | 2,12 | •E | 2,43 | 2,31 | •E | 3,26 | 3,2 | 3,02 | ||||||||
I | kW | 1,5 | •E | 1,34 | 1,92 | 2,19 | •E | 2,06 | 3,07 | •E | 2,59 | •E | 2,53 | •E | ||||||
Air flow speed | VI | m³/h | 339 | 339 | • | 484 | • | 547 | 547 | • | 676 | 681 | • | 681 | • | |||||
V | m³/h | 288 | • | 288 | 405 | 483 | • | 483 | 587 | • | 627 | 627 | ||||||||
IV | m³/h | 238 | 238 | • | 339 | • | 434 | 434 | • | 472 | 474 | • | 474 | • | ||||||
III | m³/h | 207 | • | 207 | 281 | 383 | • | 383 | 419 | • | 431 | 431 | ||||||||
II | m³/h | 177 | 177 | • | 252 | • | 329 | 321 | • | 390 | 392 | 392 | ||||||||
I | m³/h | 155 | • | 155 | 217 | 281 | • | 281 | 365 | • | 338 | • | 338 | • | ||||||
Sound power | VI | dB(A) | 48 | 48 | •E | 48 | •E | 50 | 50 | •E | 51 | 52 | •E | 52 | •E | |||||
V | dB(A) | 44 | •E | 44 | 42 | 46 | •E | 47 | 48 | •E | 50 | 50 | ||||||||
IV | dB(A) | 41 | 40 | •E | 38 | •E | 43 | 43 | •E | 43 | 43 | •E | 43 | •E | ||||||
III | dB(A) | 38 | •E | 35 | 33 | 40 | •E | 40 | 40 | •E | 41 | 41 | ||||||||
II | dB(A) | 34 | 32 | •E | 30 | •E | 36 | 36 | •E | 38 | 38 | 38 | ||||||||
I | dB(A) | 30 | •E | 31 | 26 | 35 | •E | 34 | 35 | •E | 35 | •E | 35 | •E | ||||||
❻ | Sound pressure | VI | dB(A) | 39 | 39 | • | 39 | • | 41 | 41 | • | 42 | 43 | • | 43 | • | ||||
V | dB(A) | 35 | • | 35 | 33 | 37 | • | 38 | 39 | • | 41 | 41 | ||||||||
IV | dB(A) | 32 | 31 | • | 29 | • | 34 | 34 | • | 34 | 34 | • | 34 | • | ||||||
III | dB(A) | 29 | • | 26 | 24 | 31 | • | 31 | 31 | • | 32 | 32 | ||||||||
II | dB(A) | 25 | 23 | • | 21 | • | 27 | 27 | • | 29 | 29 | 29 | ||||||||
I | dB(A) | 21 | • | 22 | 17 | 26 | • | 25 | 26 | • | 26 | • | 26 | • | ||||||
Absorbed power | VI | W | 40 | 41 | •E | 56 | •E | 60 | 65 | •E | 72 | 70 | •E | 76 | •E | |||||
V | W | 36 | •E | 32 | 42 | 54 | •E | 58 | 58 | •E | 61 | 66 | ||||||||
IV | W | 25 | 25 | •E | 32 | •E | 36 | 39 | •E | 42 | 41 | •E | 44 | •E | ||||||
III | W | 23 | •E | 21 | 27 | 31 | •E | 33 | 34 | •E | 36 | 39 | ||||||||
II | W | 17 | 16 | •E | 21 | •E | 27 | 27 | •E | 33 | 31 | 33 | ||||||||
I | W | 15 | •E | 14 | 20 | 25 | •E | 25 | 28 | •E | 28 | •E | 30 | •E | ||||||
Electrical supply | V-ph-Hz | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | 230-1-50 | |||||||||||
DIMENSIONS AND WEIGHT | 20 | 24 | 25 | 30 | 34 | 40 | 45 | 48 | ||||||||||||
L – IVP-IXP Width | mm | 550 | 550 | 750 | 750 | 750 | 950 | 950 | 950 | |||||||||||
H – IVP-IXP Height | mm | 545 | 545 | 545 | 545 | 545 | 545 | 545 | 545 | |||||||||||
P – IVP-IXP Depth | mm | 212 | 212 | 212 | 212 | 212 | 212 | 212 | 212 | |||||||||||
IVP-IXP Weight | kg | 16,5 | 17 | 20,5 | 20,5 | 21,5 | 24 | 25,5 | 27 | |||||||||||
COVER for Yardy | 20 | 24 | 25 | 30 | 34 | 40 | 45 | 48 | ||||||||||||
KCASE formwork | WxHxD | mm | 920x790x225 | 920x790x225 | 1125x790x225 | 1125x790x225 | 1125x790x225 | 1325x790x225 | 1325x790x225 | 1325x790x225 | ||||||||||
KCASE formwork | Weight | kg | 13 | 13 | 15 | 15 | 15 | 17 | 17 | 17 | ||||||||||
KPVCASE – KPXCASE panel | WxHxD | mm | 975x820x10 | 975x820x10 | 1175x820x10 | 1175x820x10 | 1175x820x10 | 1375x820x10 | 1375x820x10 | 1375x820x10 | ||||||||||
KPVCASE – KPXCASE panel | Weight | kg | 9 | 9 | 10 | 10 | 10 | 11 | 11 | 11 | ||||||||||
KGMD delivery nozzle | WxHxD | mm | 555x205x6 | 555x205x6 | 755x205x6 | 755x205x6 | 755x205x6 | 955x205x6 | 955x205x6 | 955x205x6 | ||||||||||
- Data at the following conditions:
- ❶ Air: 27°C D.B.; 19°C W.B. – Water: 7/12°C.
- ❷ Air: 20°C – Water: 45/40°C.
- ❸ Air: 20°C – Water: 50°C, flow rate as in cooling.
- ❹ Air: 20°C – Water: 70/60°C.
- ❺ Air: 20°C – Water: 65/55°C.
- ❻ For room volume equal to 100 m³ and reverberation time = 0.5 sec.
- E Eurovent certified performance.
- Performance refers to the motor’s input signal: 10V – 6V – 1V at MAX – MED – MIN speed.
- YARDY-I EV3 24 – 34 – 48 – 74 – 88 with oversized 4-row coil.
- Data at the following conditions:
- ❶ Air: 27°C D.B.; 19°C W.B. – Water: 7/12°C.
- ❷ Air: 20°C – Water: 45/40°C.
- ❸ Air: 20°C – Water: 50°C, flow rate as in cooling.
- ❹ Air: 20°C – Water: 70/60°C.
- ❺ Air: 20°C – Water: 65/55°C.
- ❻ For room volume equal to 100 m³ and reverberation time = 0.5 sec.
- • Wired speed in terminal block.
- E Eurovent certified performance.
- Yardy EV3 24 – 34 – 48 – 74 – 88 with oversized 4-row coil.
- For the selection with Air’Suite filter, refer to the UP-TO-DATE selection Software.
Manuals
To view all the documents, log in to the reserved area
Technical notes
To view all the documents, log in to the reserved area
Documents
To view all the documents, log in to the reserved area
Request information about this product
Find a reseller in your area for a customized offer on Rhoss air conditioning solutions.